Evidence map›Paper›PMID 35369885›Full record

ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2022

Reproducibility of global and segmental myocardial strain using cine DENSE at 3 T: a multicenter cardiovascular magnetic resonance study in healthy subjects and patients with heart disease.

Daniel A Auger, Sona Ghadimi, Xiaoying Cai, Claire E Reagan, Changyu Sun, Mohamad Abdi, Jie Jane Cao, Joshua Y Cheng, Nora Ngai, Andrew D Scott and 10 more

Open access · goldAbstract readMulticenter Study
In one paragraph

Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed, 1 pooled it
3.6field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 1 synthesis or guideline pooled it, 26 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Automated segmentation of long and short axis DENSE cardiovascular magnetic resonance for myocardial strain analysis using spatio-temporal convolutional neural networks.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023
    Article
  14. Article
  15. Article
  16. Review
  17. Reproducibility of circumferential strain on cine displacement encoding with stimulated echoes magnetic resonance imaging before and after contrast at 3T.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

20 authors at 8 institutions in 3 countries.

Daniel A AugerDepartment of Biomedical Engineering, University of Virginia, Box 800759, Charlottesville, VA, 22908, USA.
Sona GhadimiDepartment of Biomedical Engineering, University of Virginia, Box 800759, Charlottesville, VA, 22908, USA.
Xiaoying CaiSiemens Healthineers, Boston, Massachusetts, USA.
Claire E ReaganDepartment of Biomedical Engineering, University of Virginia, Box 800759, Charlottesville, VA, 22908, USA.
Changyu SunDepartment of Biomedical Engineering, University of Virginia, Box 800759, Charlottesville, VA, 22908, USA.
Mohamad AbdiDepartment of Biomedical Engineering, University of Virginia, Box 800759, Charlottesville, VA, 22908, USA.
Jie Jane CaoSt. Francis Hospital, The Heart Center, Long Island, NY, USA.
Joshua Y ChengSt. Francis Hospital, The Heart Center, Long Island, NY, USA.
Nora NgaiSt. Francis Hospital, The Heart Center, Long Island, NY, USA.
Andrew D ScottCardiovascular Magnetic Resonance Unit, The Royal Brompton Hospital and National Heart and Lung Institute, Imperial College London, London, UK.
Pedro F FerreiraCardiovascular Magnetic Resonance Unit, The Royal Brompton Hospital and National Heart and Lung Institute, Imperial College London, London, UK.
John N OshinskiDepartment of Radiology & Imaging Sciences and Biomedical Engineering, Emory University, Atlanta, Georgia.
Nick EmamifarDepartment of Radiology & Imaging Sciences and Biomedical Engineering, Emory University, Atlanta, Georgia.
Daniel B EnnisDepartment of Radiology, Stanford University, Stanford, CA, USA.
Michael LoecherDepartment of Radiology, Stanford University, Stanford, CA, USA.
Zhan-Qiu LiuDepartment of Radiology, Stanford University, Stanford, CA, USA.
Pierre CroisilleUniversity of Lyon, UJM-Saint-Etienne, INSA, CNRS UMR 5520, INSERM U1206, CREATIS, Saint-Etienne, France.
Magalie ViallonUniversity of Lyon, UJM-Saint-Etienne, INSA, CNRS UMR 5520, INSERM U1206, CREATIS, Saint-Etienne, France.
Kenneth C BilchickRadiology and Medical Imaging, University of Virginia Health System, Charlottesville, VA, USA.
Frederick H EpsteinDepartment of Biomedical Engineering, University of Virginia, Box 800759, Charlottesville, VA, 22908, USA. fhe6b@virginia.edu.ORCID 0000-0002-1954-1988
University of Virginia · USStanford University · USSt. Francis Hospital · USEmory University · USRoyal Brompton Hospital · GBUniversité Claude Bernard Lyon 1 · FRUniversity of Virginia Health System · USDigital Science (United States) · US

Funding

Multiscale Models for Predicting Short and Long-term Outcome of Cardiac Resynchronization TherapyR01HL159945 · NHLBI · UNIVERSITY OF VIRGINIA · PI BILCHICK, KENNETH C, HOLMES, JEFFREY W · 2021 to 2024
$2.6M
Free-breathing and simultaneous multislice cine DENSE myocardial strain imagingR01HL147104 · NHLBI · UNIVERSITY OF VIRGINIA · PI EPSTEIN, FREDERICK H · 2019 to 2022
$1.5M
British Heart Foundation RG/19/1/34160NHLBI NIH HHS R01 HL147104NHLBI NIH HHS R01 HL159945
6 · The paper itself

Abstract

backgroundWhile multiple cardiovascular magnetic resonance (CMR) methods provide excellent reproducibility of global circumferential and global longitudinal strain, achieving highly reproducible segmental strain is more challenging. Previous single-center studies have demonstrated excellent reproducibility of displacement encoding with stimulated echoes (DENSE) segmental circumferential strain. The present study evaluated the reproducibility of DENSE for measurement of whole-slice or global circumferential (E

methodsSix centers participated and a total of 81 subjects were studied, including 60 healthy subjects and 21 patients with various types of heart disease. CMR utilized 3 T scanners, and cine DENSE images were acquired in three short-axis planes and in the four-chamber long-axis view. During one imaging session, each subject underwent two separate DENSE scans to assess inter-scan reproducibility. Each subject was taken out of the scanner and repositioned between the scans. Intra-user, inter-user-same-site, inter-user-different-site, and inter-user-Human-Deep-Learning (DL) comparisons assessed the reproducibility of different users analyzing the same data. Inter-scan comparisons assessed the reproducibility of DENSE from scan to scan. The reproducibility of whole-slice or global E

resultsBased on CV and ICC, segmental E

conclusionsMulticenter data show that 3 T CMR DENSE provides highly reproducible whole-slice and segmental E

Indexed as

Heart DiseasesMagnetic Resonance Imaging, CineHealthy VolunteersHumansMagnetic Resonance SpectroscopyPredictive Value of TestsReproducibility of ResultsCMRDENSEMyocardial strain imagingReproducibility

Identifiers

PMID35369885
PMCPMC8978361
OpenAlexW4225522877

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.