ArticleActa biomaterialia2022

Improved biocompatibility of Zn-Ag-based stent materials by microstructure refinement.

Roger J Guillory, Ehsan Mostaed, Alexander A Oliver, Lea M Morath, Elisha J Earley, Katie L Flom, Timothy M Kolesar, Ali Mostaed, Henry D Summers, Maria P Kwesiga and 4 more

Open access · greenAbstract read
In one paragraph

Article in Acta biomaterialia, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
3.6field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 51 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Insights into the biological effects of molybdenum in an insect model (Frontiers in bioengineering and biotechnology · 2026
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Progress in research and development of biodegradable metallic vascular stents.Zhong nan da xue xue bao. Yi xue ban = Journal of Central South University. Medical sciences · 2024
    Review
  13. Thrombogenicity of biodegradable metals.Bioactive materials · 2024
    Article
  14. Article
  15. Naphthalene Diimide-Based Metallacage as an Artificial Ion Channel for Chloride Ion Transport.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Article
  16. Review
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors at 3 institutions in 2 countries.

Roger J GuilloryDepartment of Biomedical Engineering, Michigan Technological University, USA. Electronic address: rjguillo@mtu.edu.
Ehsan MostaedDepartment of Materials Science and Engineering, Michigan Technological University, USA.
Alexander A OliverDepartment of Biomedical Engineering, Michigan Technological University, USA; Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA.
Lea M MorathDepartment of Biomedical Engineering, Michigan Technological University, USA.
Elisha J EarleyDepartment of Biomedical Engineering, Michigan Technological University, USA.
Katie L FlomDepartment of Biomedical Engineering, Michigan Technological University, USA.
Timothy M KolesarDepartment of Biomedical Engineering, Michigan Technological University, USA.
Ali MostaedDepartment of Materials Science and Engineering, University of Sheffield, Sheffield S1 3JD, UK.
Henry D SummersDepartment of Materials Science and Engineering, Michigan Technological University, USA.
Maria P KwesigaDepartment of Biomedical Engineering, Michigan Technological University, USA.
Jaroslaw W DrelichDepartment of Materials Science and Engineering, Michigan Technological University, USA.
Kent D CarlsonDepartment of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA.
Dan Dragomir-DaescuDepartment of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA.
Jeremy GoldmanDepartment of Biomedical Engineering, Michigan Technological University, USA. Electronic address: jgoldman@mtu.edu.
Michigan Technological University · USMayo Clinic in Florida · USUniversity of Sheffield · GB

Funding

Corrosion Fatigue Resistant and Intimal Hyperplasia Suppressive Biometal for Bioabsorbable StentsR01HL144739 · NHLBI · MICHIGAN TECHNOLOGICAL UNIVERSITY · PI DRELICH, JAROSLAW W · 2019 to 2021
$1.1M
Inhibition of Neointimal Hyperplasia by Zinc-Based Biodegradable Arterial DevicesR15HL147299 · NHLBI · MICHIGAN TECHNOLOGICAL UNIVERSITY · PI GOLDMAN, JEREMY · 2019 to 2019
$611k
NHLBI NIH HHS R01 HL144739NHLBI NIH HHS R15 HL147299
6 · The paper itself

Abstract

The metallurgical engineering of bioresorbable zinc (Zn)-based medical alloys would greatly benefit from clarification of the relationships between material properties and biological responses. Here we investigate the biocompatibility of three Zn-based silver (Ag)-containing alloys, ranging from binary to quinary alloy systems. Selected binary and quinary Zn-Ag-based alloys underwent solution treatment (ST) to increase the solubility of Ag-rich phases within the Zn bulk matrix, yielding two different microstructures (one without ST and a different one with ST) with the same elemental composition. This experimental design was intended to clarify the relationship between elemental profile/microstructure and biocompatibility for the Zn-Ag system. We found that the quinary alloy system (Zn-4Ag-0.8Cu-0.6Mn-0.15Zr) performed significantly better, in terms of histomorphometry, than any alloy system we have evaluated to date. Furthermore, when solution treated to increase strength and ductility and reduce the fraction of Ag-rich phases, the quinary alloy's biocompatibility further improved. In vitro corrosion testing and metallographic analysis of in vivo implants demonstrated a more uniform mode of corrosion for the solution treated alloy. We conclude that Zn-Ag alloys can be engineered through alloying to substantially reduce neointimal growth. The positive effect on neointimal growth can be further enhanced by dissolving the AgZn

Indexed as

AlloysZincAbsorbable ImplantsBiocompatible MaterialsCorrosionMaterials TestingStentsAlloysBiocompatible MaterialsZincAlloysBiodegradableMetalSilverStentsZinc

Identifiers

PMID35367631
PMCPMC9189758
OpenAlexW4220679763

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.