Evidence map›Paper›PMID 35366875›Full record

ArticleBMC oral health2022

Selection of 1-mm venting or 2.5-mm screw access holes on implant crowns based on cement extrusion and retention capacity.

Huangjun Zhou, Sixian Ye, Min Liu, Hao Feng, Cai Wen

Open access · goldAbstract read
In one paragraph

Article in BMC oral health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Huangjun ZhouDepartment of Oral Implantology, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China.
Sixian YeDepartment of Oral Implantology, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China.
Min LiuLuzhou Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China.
Hao FengLuzhou Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China.
Cai WenDepartment of Oral Implantology, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China. wencai@swmu.edu.cn.ORCID 0000-0002-3400-5382
Southwest Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis in vitro study aimed to provide evidence regarding the selection of hole diameters of implant crowns to reduce excess cement extrusion at the abutment margin, and to examine the maintenance of their retention capacity in anterior and posterior cement-retained implant crowns.

methodsSix groups of implant crowns were prepared according to the position of the teeth and the size of their holes as follows: anterior crown without hole (ANH), anterior crown with 1-mm mini venting hole (AMH), anterior crown with 2.5-mm regular screw access hole (ARH), posterior crown without hole (PNH), posterior crown with 1-mm mini venting hole (PMH), and posterior crown with 2.5-mm regular screw access hole (PRH). Temporary cement was used to bond the crowns to the abutments. The mean amount of excess cement extrusion among the different groups at the abutment margin was calculated. Retentive strength under different hole designs was measured as the dislocation force of the crown using a universal testing machine. One-way ANOVA and Welch's t-test were used to analyze the results.

resultsThe average amounts of extruded excess cement were 18.96 ± 0.64, 1.78 ± 0.41, and 1.30 ± 0.41 mg in the ANH, AMH, and ARH groups, respectively, and 14.87 ± 0.36, 1.51 ± 0.40, and 0.82 ± 0.22 mg in the PNH, PMH, and PRH groups, respectively. The hole opening in the crowns could significantly reduce residual cement regardless of its size (p < 0.001). The mean retentive strengths were 54.16 ± 6.00, 47.63 ± 13.54, and 31.99 ± 7.75 N in the ANH, AMH, and ARH groups, respectively, and 57.84 ± 10.19, 53.22 ± 6.98, and 39.48 ± 5.12 N in the PNH, PMH, and PRH groups, respectively. The retention capacity of the implant crown deteriorated rapidly as the holes on the crown surface enlarged.

conclusionsThe presence of a hole on the implant crown reduced the amount of excess cement. The retention ability of the implant crowns deteriorated as the size of the hole increased. Considering the esthetic effect of the crown and the possible influence on crown retention, an implant crown with a 1-mm mini venting hole is a better clinical choice than the one with a 2.5-mm regular screw access hole.

Indexed as

Dental AbutmentsDental ImplantsBone ScrewsCementationCrownsDental Prosthesis, Implant-SupportedHumansDental ImplantsCement-retainedExcess cementHole diameterImplant crownRetentive strengthScrew access hole

Identifiers

PMID35366875
PMCPMC8976311
OpenAlexW4225538025

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.