Evidence map›Paper›PMID 35365688›Full record

ArticleScientific reports2022

Anatomical considerations for appropriate mini-plate positioning in open-door laminoplasty to avoid plate impingement and screw facet violation.

Jae Jun Yang, Sehan Park

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 49% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Clinical efficacy and safety analysis of the "Pre-set screw path technique" in cervical posterior single door laminoplasty with supportive titanium plate fixation: a prospective randomized controlled study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Trial
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Jae Jun YangDepartment of Orthopedic Surgery, Dongguk University Ilsan Hospital, 14 Siksadong, Ilsandong-gu, Goyang-si, Gyeonggi-do, 411-773, Republic of Korea.
Sehan ParkDepartment of Orthopedic Surgery, Dongguk University Ilsan Hospital, 14 Siksadong, Ilsandong-gu, Goyang-si, Gyeonggi-do, 411-773, Republic of Korea. birdone86@gmail.com.
Dongguk University Ilsan Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to describe a safe zone for mini-plate positioning that can avoid instrument-related complications in laminoplasty. Fifty-one patients who underwent laminoplasty and were followed up for at least 1 year were retrospectively reviewed. The posterior surface length and inferior pole angle of the lateral mass were measured at each level using computed tomography. The safe zone was defined based on these measurements. Incidences of screw facet violation and plate impingement were recorded. Patient-reported outcome measures were compared between the appropriate position (AP) and inappropriate position (IP) groups. Among 40 patients included, 15 (37.5%) had inappropriate plate positioning, causing screw facet violation or plate impingement, which more commonly occurred at distal (C5, C6) and proximal (C3, C4) levels, respectively. Lateral mass posterior surface length was shorter at the proximal levels, and the inferior pole angle of the lateral mass was smaller at the distal levels, signifying that the lateral mass became thin and long at the distal levels. Patient-reported outcome measures were not significantly different between the two groups. However, cervical range of motion at the final follow-up was significantly less in the IP group (p = 0.01). The suggested safe zone demonstrates that inserting the mini-plate with plate-to-lateral mass inferior pole distances of 4-5 mm and 5-6 mm at the C3-C5 and C6-C7 levels, respectively, would avoid instrument-related complications. The risk of plate impingement was higher at the proximal level, whereas the risk of screw facet violation was higher at the distal level in open-door cervical laminoplasty. These risks coincide with anatomical differences at each level. Despite inappropriate positioning of the mini-plate, clinical outcomes were not adversely affected.

Indexed as

LaminoplastyBone PlatesBone ScrewsCervical VertebraeHumansRetrospective Studies

Identifiers

PMID35365688
PMCPMC8975807
OpenAlexW4226154294

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked