Evidence map›Paper›PMID 35362273›Full record

ArticleJournal of biomedical optics2022

High-resolution three-dimensional blood flow tomography in the subdiffuse regime using laser speckle contrast imaging.

Chakameh Z Jafari, Samuel A Mihelic, Shaun Engelmann, Andrew K Dunn

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical optics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.2field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Chakameh Z JafariThe University of Texas at Austin, Department of Electrical and Computer Engineering, Austin, Texas, United States.
Samuel A MihelicThe University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas, United States.
Shaun EngelmannThe University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas, United States.
Andrew K DunnThe University of Texas at Austin, Department of Electrical and Computer Engineering, Austin, Texas, United States.
The University of Texas at Austin · US

Funding

Optical Imaging of Baseline Blood Flow and Oxygenation During StrokeR01EB011556 · NIBIB · UNIVERSITY OF TEXAS AT AUSTIN · PI DUNN, ANDREW K · 2010 to 2018
$3.1M
Longitudinal Imaging of Cortical Small Vessel Network Structure with Two-Color Multiphoton Fluorescence MicroscopyR01NS108484 · NINDS · UNIVERSITY OF TEXAS AT AUSTIN · PI DUNN, ANDREW K · 2018 to 2022
$2.8M
Comprehensive Training Program in Imaging Science and InformaticsT32EB007507 · NIBIB · UNIVERSITY OF TEXAS AT AUSTIN · PI MARKEY, MIA K, RYLANDER, HENRY GRADY · 2009 to 2024
$2.7M
Microscale Oxygenation Mapping During StrokeR01NS082518 · NINDS · UNIVERSITY OF TEXAS AT AUSTIN · PI DUNN, ANDREW K · 2013 to 2017
$1.7M
NIBIB NIH HHS R01 EB011556NIBIB NIH HHS T32 EB007507NINDS NIH HHS R01 NS082518NINDS NIH HHS R01 NS108484
6 · The paper itself

Abstract

significanceVisualizing high-resolution hemodynamics in cerebral tissue over a large field of view (FOV), provides important information in studying disease states affecting the brain. Current state-of-the-art optical blood flow imaging techniques either lack spatial resolution or are too slow to provide high temporal resolution reconstruction of flow map over a large FOV.

aimWe present a high spatial resolution computational optical imaging technique based on principles of laser speckle contrast imaging (LSCI) for reconstructing the blood flow maps in complex tissue over a large FOV provided that the three-dimensional (3D) vascular structure is known or assumed. APPROACH: Our proposed method uses a perturbation Monte Carlo simulation of the high-resolution 3D geometry for both accurately deriving the speckle contrast forward model and calculating the Jacobian matrix used in our reconstruction algorithm to achieve high resolution. Given the convex nature of our highly nonlinear problem, we implemented a mini-batch gradient descent with an adaptive learning rate optimization method to iteratively reconstruct the blood flow map. Specifically, we implemented advanced optimization techniques combined with efficient parallelization and vectorization of the forward and derivative calculations to make reconstruction of the blood flow map feasible with reconstruction times on the order of tens of minutes.

resultsWe tested our reconstruction algorithm through simulation of both a flow phantom model as well as an anatomically correct murine cerebral tissue and vasculature captured via two-photon microscopy. Additionally, we performed a noise study, examining the robustness of our inverse model in presence of 0.1% and 1% additive noise. In all cases, the blood flow reconstruction error was <2  %   for most of the vasculature, except for the peripheral vasculature which suffered from insufficient photon sampling. Descending vasculature and deeper structures showed slightly higher sensitivity to noise compared with vasculature with a horizontal orientation at the more superficial layers. Our results show high-resolution reconstruction of the blood flow map in tissue down to 500  μm and beyond.

conclusionsWe have demonstrated a high-resolution computational imaging technique for visualizing blood flow map in complex tissue over a large FOV. Once a high-resolution structural image is captured, our reconstruction algorithm only requires a few LSCI images captured through a camera to reconstruct the blood flow map computationally at a high resolution. We note that the combination of high temporal and spatial resolution of our reconstruction algorithm makes the solution well-suited for applications involving fast monitoring of flow dynamics over a large FOV, such as in functional neural imaging.

Indexed as

HemodynamicsLaser Speckle Contrast ImagingAlgorithmsAnimalsCerebrovascular CirculationMiceTomography, X-Ray Computedadvanced optimizationblood flow tomographyconvex nonlinear optimizationlarge-scale inverse problemlaser speckle contrast imagingperturbation Monte Carlostochastic gradient descent

Identifiers

PMID35362273
PMCPMC8968074
OpenAlexW4220894067

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.