ArticleBMC cardiovascular disorders2022
Preprocedural and procedural variables that predict new-onset conduction disturbances after transcatheter aortic valve replacement.
Article in BMC cardiovascular disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 12 citations in OpenAlex.
- Comparison of the Self-Expandable Intra-Annular Navitor Prosthesis with the Balloon-Expandable, Intra-Annular Sapien 3 Prosthesis: A Propensity-Matched Analysis.Journal of clinical medicine · 2026Article
- Conduction Disorders: The Achilles' Heel of TAVR?Journal of clinical medicine · 2026Review
- Delayed complete atrioventricular block 11 months after transcatheter aortic valve replacement in a patient with a short membranous septum: a case report.Frontiers in cardiovascular medicine · 2026Article
- Assessing post-TAVR cardiac conduction abnormalities risk using an electromechanically coupled beating heart.Biomechanics and modeling in mechanobiology · 2025Article
- Impact of prosthesis oversizing on clinical outcomes of transcatheter aortic valve implantation using a self-expandable Evolut R valve.The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology · 2024Article
- Predictors, clinical impact, and management strategies for conduction abnormalities after transcatheter aortic valve replacement: an updated review.Frontiers in cardiovascular medicine · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundConduction disturbances are a common complication after transcatheter aortic valve replacement (TAVR). The aim of this study was to investigate the preprocedural and procedural variables that predict new-onset conduction disturbances post-TAVR (hereafter CD/CDs).
methodsConsecutive patients who underwent TAVR during December 2009-March 2021 at the Faculty of Medicine Siriraj Hospital, Mahidol University-Thailand's largest national tertiary referral center-were enrolled. Patients with prior implantation of a cardiac device, periprocedural death, or unsuccessful procedure were excluded. Clinical and electrocardiographic data, preprocedural imaging, including membranous septum (MS) length, and procedural variables, including implantation depth (ID), were analyzed. CD was defined as new left or right bundle branch block, significant intraventricular conduction disturbance with QRS interval ≥ 120 ms, new high-grade atrioventricular block, or complete heart block. Multivariate binary logistic analysis and receiver operating characteristic (ROC) curve analysis were used to identify independent predictors and the optimal ∆MSID (difference between the MS length and ID) cutoff value, respectively.
resultsA total of 124 TAVR patients (mean age: 84.3 ± 6.3 years, 62.1% female) were included. The mean Society of Thoracic Surgeons score was 7.3%, and 85% of patients received a balloon expandable transcatheter heart valve. Thirty-five patients (28.2%) experienced a CD, and one-third of those required pacemaker implantation. The significant preprocedural and procedural factors identified from univariate analysis included intraventricular conduction delay, mitral annular calcification, MS length ≤ 6.43 mm, self-expanding device, small left ventricular cavity, and ID ≥ 6 mm. Multivariate analysis revealed MS length ≤ 6.43 mm (adjusted odds ratio [aOR] 9.54; 95% CI 2.56-35.47; p = 0.001) and ∆MSID < 0 mm (adjusted odds ratio [aOR] 10.77; 95% CI 2.86-40.62; p = < 0.001) to be independent predictors of CD. The optimal ∆MSID cutoff value for predicting conduction disturbances was less than 0 mm (area under the receiver operating characteristic curve [AuROC]: 0.896).
conclusionThis study identified MS length ≤ 6.43 mm and ∆MSID < 0 mm as independent predictors of CDs. ∆MSID < 0 was the strongest and only modifiable predictor. Importantly, we expanded the CD criteria to cover all spectrum of TAVR-related conduction injury to lower the threshold of this sole modifiable risk. The optimal ∆MSID cutoff value was < 0 mm.
trial registrationTCTR, TCTR20210818002. Registered 17 August 2021-Retrospectively registered, http://www.thaiclinicaltrials.org/show/TCTR 20210818002.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.