Evidence map›Paper›PMID 35358390›Full record

ArticleJournal of the American Society for Mass Spectrometry2022

Evaluation of 6 MALDI-Matrices for 10 μm Lipid Imaging and On-Tissue MSn with AP-MALDI-Orbitrap.

Tina B Angerer, Jerome Bour, Jean-Luc Biagi, Eugene Moskovets, Gilles Frache

Open access · hybridAbstract read
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 33 papers.

0numbers the graph read from it
0cells of the map it votes in
33citing papers in PubMed
6.6field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

33 citing papers in PubMed, 64 citations in OpenAlex.

  1. Review
  2. Review
  3. Enhancing the Sensitivity of Mass Spectrometry Imaging through Spatial Signal Averaging.Journal of the American Society for Mass Spectrometry · 2026
    Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Quantitative mass spectrometry imaging: therapeutics & biomolecules.Chemical communications (Cambridge, England) · 2024
    Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Tina B AngererLuxembourg Institute of Science and Technology (LIST), Advanced Characterization platform, Materials Research and Technology, 41, rue du Brill, L-4422 Belvaux, Luxembourg.ORCID 0000-0003-3852-6254
Jerome BourLuxembourg Institute of Science and Technology (LIST), Advanced Characterization platform, Materials Research and Technology, 41, rue du Brill, L-4422 Belvaux, Luxembourg.
Jean-Luc BiagiLuxembourg Institute of Science and Technology (LIST), Advanced Characterization platform, Materials Research and Technology, 41, rue du Brill, L-4422 Belvaux, Luxembourg.
Eugene MoskovetsMassTech, Inc., Columbia, Maryland 21046, United States.
Gilles FracheLuxembourg Institute of Science and Technology (LIST), Advanced Characterization platform, Materials Research and Technology, 41, rue du Brill, L-4422 Belvaux, Luxembourg.ORCID 0000-0003-0069-9475
Luxembourg Institute of Science and Technology · LUMassTech (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Mass spectrometry imaging is a technique uniquely suited to localize and identify lipids in a tissue sample. Using an atmospheric pressure (AP-) matrix-assisted laser desorption ionization (MALDI) source coupled to an Orbitrap Elite, numerous lipid locations and structures can be determined in high mass resolution spectra and at cellular spatial resolution, but careful sample preparation is necessary. We tested 11 protocols on serial brain sections for the commonly used MALDI matrices CHCA, norharmane, DHB, DHAP, THAP, and DAN in combination with tissue washing and matrix additives to determine the lipid coverage, signal intensity, and spatial resolution achievable with AP-MALDI. In positive-ion mode, the most lipids could be detected with CHCA and THAP, while THAP and DAN without additional treatment offered the best signal intensities. In negative-ion mode, DAN showed the best lipid coverage and DHAP performed superiorly for gangliosides. DHB produced intense cholesterol signals in the white matter. One hundred fifty-five lipids were assigned in positive-ion mode (THAP) and 137 in negative-ion mode (DAN), and 76 peaks were identified using on-tissue tandem-MS. The spatial resolution achievable with DAN was 10 μm, confirmed with on tissue line-scans. This enabled the association of lipid species to single neurons in AP-MALDI images. The results show that the performance of AP-MALDI is comparable to vacuum MALDI techniques for lipid imaging.

Indexed as

Atmospheric PressureLipidsBrainSpectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationLipidsAP-MALDIlipidsmass spectrometry imagingsample preparationtandem-MS

Identifiers

PMID35358390
PMCPMC9074099
OpenAlexW4220700857

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.