Evidence map›Paper›PMID 35354848›Full record

ArticleScientific reports2022

Acoustic levitation and rotation of thin films and their application for room temperature protein crystallography.

Michal W Kepa, Takashi Tomizaki, Yohei Sato, Dmitry Ozerov, Hiroshi Sekiguchi, Nobuhiro Yasuda, Koki Aoyama, Petr Skopintsev, Jörg Standfuss, Robert Cheng and 2 more

Erratum issuedAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

12 authors.

Michal W KepaDivision of Biology and Chemistry, Paul Scherrer Institut, 5232, Villigen-PSI, Switzerland.
Takashi TomizakiPhoton Science Division, Paul Scherrer Institut, 5232, Villigen-PSI, Switzerland. takashi.tomizaki@psi.ch.
Yohei SatoNuclear Energy and Safety Research Division, Paul Scherrer Institut, 5232, Villigen-PSI, Switzerland.
Dmitry OzerovPhoton Science Division, Paul Scherrer Institut, 5232, Villigen-PSI, Switzerland.
Hiroshi SekiguchiJapan Synchrotron Radiation Research Institute, Kouto 1-1-1, Sayo-cho, Sayo-gun, Hyogo, 679-5198, Japan.
Nobuhiro YasudaJapan Synchrotron Radiation Research Institute, Kouto 1-1-1, Sayo-cho, Sayo-gun, Hyogo, 679-5198, Japan.
Koki AoyamaJapan Synchrotron Radiation Research Institute, Kouto 1-1-1, Sayo-cho, Sayo-gun, Hyogo, 679-5198, Japan.
Petr SkopintsevDivision of Biology and Chemistry, Paul Scherrer Institut, 5232, Villigen-PSI, Switzerland.
Jörg StandfussDivision of Biology and Chemistry, Paul Scherrer Institut, 5232, Villigen-PSI, Switzerland.
Robert ChengleadXpro AG, PARK InnovAARE, 5234, Villigen-PSI, Switzerland.
Michael HennigleadXpro AG, PARK InnovAARE, 5234, Villigen-PSI, Switzerland.
Soichiro TsujinoDivision of Biology and Chemistry, Paul Scherrer Institut, 5232, Villigen-PSI, Switzerland. soichiro.tsujino@psi.ch.

Funding

Marie Curie 701647Swiss National Science Foundation 200021_192772Swiss National Science Foundation 31003A_179351
6 · The paper itself

Abstract

Acoustic levitation has attracted attention in terms of chemical and biochemical analysis in combination with various analytical methods because of its unique container-less environment for samples that is not reliant on specific material characteristics. However, loading samples with very high viscosity is difficult. To expand the scope, we propose the use of polymer thin films as sample holders, whereby the sample is dispensed on a film that is subsequently loaded onto an acoustic levitator. When applied for protein crystallography experiments, rotation controllability and positional stability are important prerequisites. We therefore study the acoustic levitation and rotation of thin films with an aspect ratio (the diameter-to-thickness ratio) of 80-240, which is an order of magnitude larger than those reported previously. For films with empirically optimized shapes, we find that it is possible to control the rotation speed in the range of 1-4 rotations per second while maintaining a positional stability of 12 ± 5 µm. The acoustic radiation force acting on the films is found to be a factor of 26-30 higher than that for same-volume water droplets. We propose use cases of the developed films for protein crystallography experiments and demonstrate data collections for large single crystal samples at room temperature.

Indexed as

AcousticsProteinsCrystallographyTemperatureWaterProteinsWater

Identifiers

PMID35354848
PMCPMC8967846

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.