ReviewThe Korean journal of pain2022
Radiation safety for pain physicians: principles and recommendations.
Review in The Korean journal of pain, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- A Comparative Analysis of Ultrasound versus Fluoroscopy-Guided Transforaminal Endoscopic Lumbar Discectomy: Protocol for a Randomized Clinical Trial Targeting Lumbar Disc Herniation.Journal of pain research · 2026Article
- Real-time dosimetry in interventional radiology - comparing the occupational radiation exposure in fluoroscopy-guided lower extremity and abdominal procedures.European radiology · 2025Article
- Evaluation of a first of a kind robotic radiation protection technology to reduce scatter exposure during diagnostic procedures and percutaneous coronary interventions.American heart journal plus : cardiology research and practice · 2025Article
- Influence of Obesity, Race and Gender on Radiation Exposure for Epidural Procedures.Current pain and headache reports · 2025Review
- Clinical Application of an Augmented Reality Navigation System for Transforaminal Epidural Injection: A Randomized Controlled Trial.Journal of clinical medicine · 2024Article
- Comparison of international medical costs for interventional pain treatment: a focus on Korea and Japan.The Korean journal of pain · 2024Article
- Comment on "Comparison between the coronal diameters of the cervical spinal canal and spinal cord measured using computed tomography and magnetic resonance imaging in Korean patients".Korean journal of anesthesiology · 2023Article
- Augmented Reality-Assisted Navigation System for Transforaminal Epidural Injection.Journal of pain research · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
C-arm fluoroscopy is a useful tool for interventional pain management. However, with the increasing use of C-arm fluoroscopy, the risk of accumulated radiation exposure is a significant concern for pain physicians. Therefore, efforts are needed to reduce radiation exposure. There are three types of radiation exposure sources: (1) the primary X-ray beam, (2) scattered radiation, and (3) leakage from the X-ray tube. The major radiation exposure risk for most medical staff members is scattered radiation, the amount of which is affected by many factors. Pain physicians can reduce their radiation exposure by use of several effective methods, which utilize the following main principles: reducing the exposure time, increasing the distance from the radiation source, and radiation shielding. Some methods reduce not only the pain physician's but also the patient's radiation exposure. Taking images with collimation and minimal use of magnification are ways to reduce the intensity of the primary X-ray beam and the amount of scattered radiation. It is also important to carefully select the C-arm fluoroscopy mode, such as pulsed mode or low-dose mode, for ensuring the physician's and patient's radiation safety. Pain physicians should practice these principles and also be aware of the annual permissible radiation dose as well as checking their radiation exposure. This article aimed to review the literature on radiation safety in relation to C-arm fluoroscopy and provide recommendations to pain physicians during C-arm fluoroscopy-guided interventional pain management.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials