Evidence map›Paper›PMID 35353859›Full record

ArticlePloS one2022

Laser light sources for photobiomodulation: The role of power and beam characterization in treatment accuracy and reliability.

Carlos Eduardo Girasol, Guilherme de Araújo Braz, Luciano Bachmann, Jonathan Celli, Rinaldo Roberto de Jesus Guirro

Abstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Is photobiomodulation therapy free from racial bias?: a narrative review of skin pigmentation.Sao Paulo medical journal = Revista paulista de medicina · 2026
    Review
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Carlos Eduardo GirasolPostgraduate Program in Rehabilitation and Functional Performance, Department of Health Sciences, Ribeirão Preto Medical School, University of São Paulo (USP), Ribeirão Preto, São Paulo, Brazil.ORCID 0000-0002-3901-582X
Guilherme de Araújo BrazTechnology Center of the Supera Park of Innovation and Technology of Ribeirão Preto, Ribeirão Preto, São Paulo, Brazil.
Luciano BachmannPostgraduate Program in Physics Applied to Medicine and Biology, University of São Paulo (USP), Ribeirão Preto, São Paulo, Brazil.ORCID 0000-0001-6622-251X
Jonathan CelliDepartment of Physics, University of Massachusetts Boston, Boston, Massachusetts, United States of America.ORCID 0000-0003-3560-0770
Rinaldo Roberto de Jesus GuirroPostgraduate Program in Rehabilitation and Functional Performance, Department of Health Sciences, Ribeirão Preto Medical School, University of São Paulo (USP), Ribeirão Preto, São Paulo, Brazil.ORCID 0000-0001-7491-3388

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeDaily clinical use of therapeutic light sources can lead to changes in light emission stability with potentially significant consequences for usage in photomedicine treatment. The aim of this study was to evaluate the average and maximum power and to describe the beam diameter of different low-power laser photobiomodulation devices in clinical use in Brazil.

methodsThe power and light-emitting beam diameter of twenty-four therapeutic devices with an average age of 11±5 years, with an average weekly use of fewer than thirty minutes, were measured.

resultsThe analyzed power varied between 2% to 134% of the values declared by the manufacturers. Differences in beam diameter of between 38% and 543% of the nominal values were also observed. It is also noteworthy that even between the same brand and model, differences in diameter were obtained. Finally, differences were observed in the power output after one and three minutes of sequential emission for 830 nm and 904 nm (p < 0.05), but not when comparing the difference between wavelengths in factor time.

conclusionThere is a need for a shared effort on the part of laser manufacturers to improve standardization and consistency of laser output power and beam diameters. At the same time, medical laser operators should also consider development of standardized protocols for maintenance and monitoring equipment performance over time to correct for fluctuations that could ultimately impact on treatment outcomes.

Indexed as

LasersLow-Level Light TherapyBrazilReproducibility of ResultsTreatment Outcome

Identifiers

PMID35353859
PMCPMC8967059

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.