Evidence map›Paper›PMID 35350121›Full record

ArticleJB & JS open access

Accuracy of Stereovision-Updated Versus Preoperative CT-Based Image Guidance in Multilevel Lumbar Pedicle Screw Placement: A Cadaveric Swine Study.

Xiaoyao Fan, Sohail K Mirza, Chen Li, Linton T Evans, Songbai Ji, Keith D Paulsen

Open access · greenAbstract read
In one paragraph

Article in JB & JS open access. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Xiaoyao FanThayer School of Engineering, Dartmouth College, Hanover, New Hampshire.ORCID https://orcid.org/0000-0003-0576-0087
Sohail K MirzaThayer School of Engineering, Dartmouth College, Hanover, New Hampshire.
Chen LiThayer School of Engineering, Dartmouth College, Hanover, New Hampshire.ORCID https://orcid.org/0000-0002-0444-742X
Linton T EvansGeisel School of Medicine, Dartmouth College, Hanover, New Hampshire.ORCID https://orcid.org/0000-0001-8752-7945
Songbai JiThayer School of Engineering, Dartmouth College, Hanover, New Hampshire.ORCID https://orcid.org/0000-0002-2886-5781
Keith D PaulsenThayer School of Engineering, Dartmouth College, Hanover, New Hampshire.ORCID https://orcid.org/0000-0002-6692-3196
Dartmouth College · USDartmouth–Hitchcock Medical Center · USWorcester Polytechnic Institute · US

Funding

Image based registration and intraoperative updating for guiding spine surgeryR01EB025747 · NIBIB · DARTMOUTH COLLEGE · PI MIRZA, SOHAIL K, PAULSEN, KEITH D. · 2017 to 2020
$1.7M
NIBIB NIH HHS R01 EB025747
6 · The paper itself

Abstract

Change in vertebral position between preoperative imaging and the surgical procedure reduces the accuracy of image-guided spinal surgery, requiring repeated imaging and surgical field registration, a process that takes time and exposes patients to additional radiation. We developed a handheld, camera-based, deformable registration system (intraoperative stereovision, iSV) to register the surgical field automatically and compensate for spinal motion during surgery without further radiation exposure. Methods: We measured motion-induced errors in image-guided lumbar pedicle screw placement in 6 whole-pig cadavers using state-of-the-art commercial spine navigation (StealthStation; Medtronic) and iSV registration that compensates for intraoperative vertebral motion. We induced spinal motion by using preoperative computed tomography (pCT) of the lumbar spine performed in the supine position with accentuated lordosis and performing surgery with the animal in the prone position. StealthStation registration of pCT occurred using metallic fiducial markers implanted in each vertebra, and iSV data were acquired to perform a deformable registration between pCT and the surgical field. Sixty-eight pedicle screws were placed in 6 whole-pig cadavers using iSV and StealthStation registrations in random order of vertebral level, relying only on image guidance without invoking the surgeon's judgment. The position of each pedicle screw was assessed with post-procedure CT and confirmed via anatomical dissection. Registration errors were assessed on the basis of implanted fiducials. Results: The frequency and severity of pedicle screw perforation were lower for iSV registration compared with StealthStation (97% versus 68% with Grade 0 medial perforation for iSV and StealthStation, respectively). Severe perforation occurred only with StealthStation (18% versus 0% for iSV). The overall time required for iSV registration (computational efficiency) was ∼10 to 15 minutes and was comparable with StealthStation registration (∼10 min). The mean target registration error was smaller for iSV relative to StealthStation (2.81 ± 0.91 versus 8.37 ± 1.76 mm). Conclusions: Pedicle screw placement was more accurate with iSV registration compared with state-of-the-art commercial navigation based on preoperative CT when alignment of the spine changed during surgery. Clinical Relevance: The iSV system compensated for intervertebral motion, which obviated the need for repeated vertebral registration while providing efficient, accurate, radiation-free navigation during open spinal surgery.

Identifiers

PMID35350121
PMCPMC8937011
OpenAlexW4221085548

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.