ArticleInternational orthopaedics2022
Comminuted AO-C3 fractures of the patella: good outcome using anatomically contoured locking plate fixation.
Article in International orthopaedics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 17 citations in OpenAlex.
- Clinical outcomes of contoured dorsal mini-fragment plate fixation versus tension band wiring for transverse articular patellar fractures: a prospective observational study.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026Observational
- Low early fixation failure rates with variable-angle locking plate fixation of AO/OTA 34 C patella fractures: a retrospective cohort study.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026Article
- Clinical and functional outcomes of fracture pattern-driven plate osteosynthesis technique for comminuted patellar fractures using multiple miniplates.Archives of orthopaedic and trauma surgery · 2026Article
- Dual tension band technique for patellar fractures involving articular surface and inferior pole: a retrospective cohort study and finite element analysis.Frontiers in bioengineering and biotechnology · 2025Article
- Analysis of postoperative complications 5 years after osteosynthesis of patella fractures-a retrospective, multicenter cohort study.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024Article
- Evolution in the Management of Patella Fractures.Journal of clinical medicine · 2024Review
- Can multiple miniplates improve the treatment of comminuted patellar fracture?BMC musculoskeletal disorders · 2023Article
- High return to sports rates after operative treatment of patella fractures.European journal of medical research · 2023Article
- A study of fracture lines distribution characteristics in complete articular fractures of the patella.Frontiers in surgery · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe treatment of comminuted patellar fractures remains a challenge for orthopedic surgeons. The aim of this study was to assess the clinical, functional, and radiological outcome after treatment of comminuted patellar fractures using an anatomically contoured plating system.
methodsBetween January 2015 and December 2019 (5 years), 29 patients with complex C3 fractures according to AO classification (18 female, 11 male; mean age: 53 years) were treated using an anatomically contoured plating system (patella SuturePlate™, Arthrex®, Naples, USA). Indication for surgery was based on instability and/or initial fragment dislocation (> 2 mm). After a minimum follow-up of 12 months, patients were examined using a standardized clinical examination and functional outcome was assessed using specific knee scores (Lysholm, WOMAC, IKDC, Kujala, and Tegner score). In addition, complications were recorded and all available radiographs were evaluated regarding osteoarthritis and reduction quality.
resultsAll patients returned for follow-up investigation after an average of 19 months (range: 12-48 months). A mean range of motion (ROM) of 131° (range: 100-150) was recorded. Overall good functional outcome parameters could be reported, with a mean Lysholm score of 84.7 (range: 100-45), a WOMAC of 5.1 (range: 0-19.2), a Kujala scale of 85.5 (range: 100-48), an IKDC of 76.6 (range: 100-44.8), and a Tegner score of 4.3 (range: 10-3) with a difference of 0.62 to pre-operative. Patient satisfaction was rated 8.4 (range: 4-10) using a VAS. No loss of reduction, mechanical failure, or implant complications were detected. Radiological follow-up showed no evidence of relevant post-traumatic retropatellar osteoarthritis. In 7 cases, implants were removed due to subjective mechanical irritation.
conclusionAnatomically contoured patellar plates allow secure fixation of the fracture fragments even in comminuted cases. Especially when tension-band wiring is prone to early failure, locking plate fixation represents a viable option leading to good functional results and low complication rates.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.