[Economic aspects of low-field magnetic resonance imaging : Acquisition, installation, and maintenance costs of 0.55 T systems].

Jan Vosshenrich, Hanns-Christian Breit, Michael Bach, Elmar M Merkle

Abstract readReview
In one paragraph

Review in Der Radiologe, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Clinical MR imaging of patients with spinal hardware at 0.55T: comparison of diagnostic assessment and metal artifact appearance with 1.5T.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025
    Article
  6. Measuring biventricular function and left atrial volume in a single five-dimensional whole-heart cardiovascular magnetic resonance scan at 0.55T.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025
    Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Review
  12. Review
  13. Review
  14. Review
  15. Review
  16. Cardiac MRI at Low Field Strengths.Journal of magnetic resonance imaging : JMRI · 2024
    Review
  17. Article
  18. Article
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jan VosshenrichKlinik für Radiologie und Nuklearmedizin, Universitätsspital Basel, Petersgraben 4, 4031, Basel, Schweiz.
Hanns-Christian BreitKlinik für Radiologie und Nuklearmedizin, Universitätsspital Basel, Petersgraben 4, 4031, Basel, Schweiz. hanns-christian.breit@usb.ch.
Michael BachKlinik für Radiologie und Nuklearmedizin, Universitätsspital Basel, Petersgraben 4, 4031, Basel, Schweiz.
Elmar M MerkleKlinik für Radiologie und Nuklearmedizin, Universitätsspital Basel, Petersgraben 4, 4031, Basel, Schweiz.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLow-field magnetic resonance imaging (MRI) scanners offer an opportunity for cost reduction in the healthcare system. This is due to lower manufacturing costs and reduced construction requirements for installation and operation.

objectivesTo discuss potential cost reductions in acquisition, installation, and maintenance by using new low-field MRI systems.

methodsWe provide an overview of key cost drivers and an evaluation of the potential savings of a recent generation 0.55T low-field MRI compared to conventional 1.5T and 3T MRI systems in routine clinical practice.

resultsIn terms of purchase price, the savings potential of a 0.55T MRI compared to a 1.5T MRI system is about 40-50%. The 25% lower weight of the system reduces the transportation costs incurred, and the smaller size of the unit allows for installation by a remotely controlled mobile robotic system without opening the exterior façade, if the operating site is at ground level. Together with the lack of need to install a quench pipe, this reduces the total cost of installation by up to 70%. The maintenance cost of a 0.55T MRI is approximately 45% less than that of a 1.5T unit with a comparable service contract. Further cost reductions result from the smaller room size and potentially lower energy consumption for examinations and cooling.

conclusionThe use of lower field strength MRI systems offers enormous economic and environmental potential for both hospitals and practice operators, as well as for the healthcare system as a whole.

Indexed as

Magnetic Resonance ImagingHumansCost–benefit analysisEnergy consumptionLow field MRIMaintenance costsMRI scanner

Identifiers

PMID35348808
PMCPMC9061693

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.