Trial report in The Angle orthodontist, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07039071 narecruitingnot on this mapstarted 2026, after this paper: background citation

Evaluation of Clinical and Patient-Reported Outcomes of Laceback: A Split-Mouth Randomised Controlled Trial

TypeinterventionalSponsorInternational Islamic University MalaysiaRan2026 to 2027Enrolled38ConditionsMalocclusionArmsLaceback
NCT07063186 nanot yet recruitingnot on this mapstarted 2025, after this paper: background citation

Comparing Ligation Methods During Canine Retraction Stage Using Conventional Brackets: A Randomized Controlled Trial

TypeinterventionalSponsorInternational Islamic University MalaysiaRan2025 to 2027Enrolled60ConditionsMalocclusion, Canine RetractionArmsGroup A - Elastomeric power chain on all bracket wings., Group B - Stainless steel ligatures with elastomeric power chain placed over all bracket wings., Group C - Elastomeric modules on mesial wings and power chain on distal wings.
3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Trial
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Serene A Badran
Juman M Al-Zaben
Lina M Al-Taie
Haya Tbeishi
Mahmoud K Al-Omiri

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo compare patient-reported pain, discomfort, and difficulty in maintaining proper brushing between nickel-titanium closed-coil springs (CS) and elastomeric power chains (PC) when used for space closure. The secondary aims were to compare plaque control and efficiency of space closure between these two force delivery systems. MATERIALS AND

methodsA total of 48 patients who required extractions of upper first premolars and distal movement of upper canines had the CS randomly allocated to either the right or left side. Blinding was applied at data collection and analysis. Primary outcomes were pain intensity measured on visual analog scale, pain onset and duration, discomfort, and difficulty in maintaining proper brushing from the start of canine retraction at baseline and at 6 and 12 weeks thereafter. Secondary outcomes were plaque scores and the rate of space closure.

resultsNo significant differences in mean pain scores, pain onset, and duration at different time intervals between CS and PC were observed. The CS side was significantly less comfortable than the PC (P < .0001) and more difficult to keep clean (P = .008). No significant differences in plaque scores were observed between CS and PC groups at any time interval. CS produced a faster rate of space closure than did PC (P = .008).

conclusionsCS were less tolerated than PC by patients but produced an average of 0.5 mm more movement than did the PC during the 12-week study period.