ArticleMagnetic resonance in medicine2022
Identifying the source of spurious signals caused by B
Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Real-time AI integration for MR to detect artifacts and guide pulse sequence adaptations.bioRxiv : the preprint server for biology · 2026Article
- Identifying Out-of-Voxel Echoes in Edited MRS With Phase Cycle Inversion.Magnetic resonance in medicine · 2026Article
- Improving magnetic field homogeneity in prostate MR imaging and spectroscopy using an add-on local external shim coil array.Magma (New York, N.Y.) · 2026Article
- Gradient Scheme Optimization for PRESS-Localized Edited MRS Using Weighted Pathway Suppression.NMR in biomedicine · 2026Article
- Gradient scheme optimization for PRESS-localized edited MRS using weighted pathway suppression.bioRxiv : the preprint server for biology · 2025Article
- Identifying out-of-voxel echoes in edited MRS with phase cycle inversion.bioRxiv : the preprint server for biology · 2025Article
- Identifying the source of spurious signals caused by BMagnetic resonance in medicine · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeSingle-voxel MRS (SV MRS) requires robust volume localization as well as optimized crusher and phase-cycling schemes to reduce artifacts arising from signal outside the volume of interest. However, due to local magnetic field gradients (B
methodsWe investigated all possible coherence pathways associated with imperfect localization in a semi-localized by adiabatic selective refocusing (semi-LASER) sequence for potential rephasing of signals arising from unwanted coherence pathways by a local magnetic field gradient. We searched for locations in the B
resultsOur analysis revealed that potential sources of spurious signals were scattered over multiple locations throughout the brain. This was confirmed by 3D-CSI data. Moreover, we showed that the number of potential locations where spurious signals could originate from monotonically decreases with crusher strength.
conclusionWe proposed a method to identify the source of spurious signals in SV
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.