Evidence map›Paper›PMID 35344594›Full record

ArticleMagnetic resonance in medicine2022

Average saturation efficiency filter (ASEF) for CEST imaging.

Tao Jin, Julius Juhyun Chung

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Tao JinDepartment of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.ORCID 0000-0003-2912-3517
Julius Juhyun ChungDepartment of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.

Funding

Magnetic Resonance Imaging of Glucose Analogs in StrokeR01NS100703 · NINDS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI JIN, TAO · 2018 to 2022
$1.6M
NINDS NIH HHS R01 NS100703
6 · The paper itself

Abstract

purposeEndogenous CEST signal usually has low specificity due to contamination from the magnetization transfer effect and from fast exchanging labile protons with close Larmor frequencies. We propose to improve CEST signal specificity with an average saturation efficiency filter (ASEF).

methodsASEF measures the difference between CEST signals acquired with similar average irradiation power but largely different duty cycles (DC), for example, a continuous wave or a high DC pulse train versus a low DC one. Simulation and Cr phantom studies were performed to evaluate the characteristics of ASEF for CEST.

resultsTheoretical and simulation studies show that ASEF can suppress fast exchanging processes, with only a small loss of chemical exchange contrast for slow-to-intermediate exchange rates if the difference in DC is large. In the RF offset range of 2 to 5 ppm with an averaged saturation power of 0.8 and 1.6 microteslas, there is a mismatch of ∼0.1% to 2% in the magnetization transfer signal between saturation by continuous wave and a pulse train with DC = 15% and pulse duration of 24 ms, respectively. This mismatch can be minimized by careful selection of saturation power, pulse duration, and DC differences or by applying a small fudge factor between the 2 irradiation powers. Phantom studies of Cr confirmed that ASEF can minimize the magnetization transfer effect and reduce sensitivity to fast exchange processes.

conclusionASEF can improve the specificity of slow-to-intermediate exchanging CEST signal with a relatively small loss of sensitivity.

Indexed as

AlgorithmsMagnetic Resonance ImagingImage EnhancementImage Interpretation, Computer-AssistedPhantoms, ImagingCESTcontinuous waveexchange rate filtermagnetization transferpulse train

Identifiers

PMID35344594
PMCPMC9172934

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.