ArticleIEEE transactions on medical imaging2022
Curvelet Transform-Based Sparsity Promoting Algorithm for Fast Ultrasound Localization Microscopy.
Article in IEEE transactions on medical imaging, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Fast 3-D Ultrasound Localization Microscopy via Projection-Based Processing Framework.IEEE transactions on medical imaging · 2026Article
- OptimizingPhysics in medicine and biology · 2025Article
- First clinical utility of sensing Ultrasound Localization Microscopy (sULM): identifying renal pseudotumors.Theranostics · 2025Article
- 3D ultrasound localization microscopy of the nonhuman primate brain.EBioMedicine · 2025Article
- Ultrasound flow imaging for assessing cerebrovascular changes following focused-ultrasound blood-brain barrier opening.Theranostics · 2025Article
- Article
- Contrast-Free Super-Resolution Power Doppler (CS-PD) Based on Deep Neural Networks.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2023Article
- Super-resolution ultrasound microvascular imaging: Is it ready for clinical use?Zeitschrift fur medizinische Physik · 2023Review
- Three-Dimensional Ultrasound Localization Microscopy with Bipartite Graph-Based Microbubble Pairing and Kalman-Filtering-Based Tracking on a 256-Channel Verasonics Ultrasound System with a 32 × 32 Matrix Array.Journal of medical and biological engineering · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
Ultrasound localization microscopy (ULM) based on microbubble (MB) localization was recently introduced to overcome the resolution limit of conventional ultrasound. However, ULM is currently challenged by the requirement for long data acquisition times to accumulate adequate MB events to fully reconstruct vasculature. In this study, we present a curvelet transform-based sparsity promoting (CTSP) algorithm that improves ULM imaging speed by recovering missing MB localization signal from data with very short acquisition times. CTSP was first validated in a simulated microvessel model, followed by the chicken embryo chorioallantoic membrane (CAM), and finally, in the mouse brain. In the simulated microvessel study, CTSP robustly recovered the vessel model to achieve an 86.94% vessel filling percentage from a corrupted image with only 4.78% of the true vessel pixels. In the chicken embryo CAM study, CTSP effectively recovered the missing MB signal within the vasculature, leading to marked improvement in ULM imaging quality with a very short data acquisition. Taking the optical image as reference, the vessel filling percentage increased from 2.7% to 42.2% using 50ms of data acquisition after applying CTSP. CTSP used 80% less time to achieve the same 90% maximum saturation level as compared with conventional MB localization. We also applied CTSP on the microvessel flow speed maps and found that CTSP was able to use only 1.6s of microbubble data to recover flow speed images that have similar qualities as those constructed using 33.6s of data. In the mouse brain study, CTSP was able to reconstruct the majority of the cerebral vasculature using 1-2s of data acquisition. Additionally, CTSP only needed 3.2s of microbubble data to generate flow velocity maps that are comparable to those using 129.6s of data. These results suggest that CTSP can facilitate fast and robust ULM imaging especially under the circumstances of inadequate microbubble localizations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials