Evidence map›Paper›PMID 35344266›Full record

ArticleJournal of applied clinical medical physics2022

Dosimetric feasibility of hippocampal avoidance whole brain radiotherapy with an MRI-guided linear accelerator.

Jasmine A Graham, Gage Redler, Kirby B Delozier, Hsiang-Hsuan Michael Yu, Daniel E Oliver, Stephen A Rosenberg

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
1.8field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it, 13 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Review
  6. Review
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Jasmine A GrahamH. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida, United States.
Gage RedlerH. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida, United States.
Kirby B DelozierH. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida, United States.
Hsiang-Hsuan Michael YuH. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida, United States.
Daniel E OliverH. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida, United States.
Stephen A RosenbergH. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida, United States.
Moffitt Cancer Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

PURPOSE/OBJECTIVE(S): Whole brain radiotherapy with hippocampal avoidance (HA-WBRT) is a technique utilized to treat metastatic brain disease while preserving memory and neurocognitive function. We hypothesized that the treatment planning and delivery of HA-WBRT plans is feasible with an MRI-guided linear accelerator (linac) and compared plan results with clinical non-MRI-guided C-Arm linac plans. MATERIALS/

methodsTwelve HA-WBRT patients treated on a non-MRI-guided C-Arm linac were selected for retrospective analysis. Treatment plans were developed using a 0.35T MRI-guided linac system for comparison to clinical plans. Treatment planning goals were defined as provided in the Phase II Trial NRG CC001. MRI-guided radiotherapy (MRgRT) treatment plans were developed by a dosimetrist and compared with clinical plans. quality assurance (QA) plans were generated and delivered on the MRI-guided linac to a cylindrical diode detector array. Planning target volume (PTV) coverage was normalized to ∼95% to provide a control point for comparison of dose to the organs at risk.

resultsMRgRT plans were deliverable and met all clinical goals. Mean values demonstrated that the clinical plans were less heterogeneous than MRgRT plans with mean PTV V37.5 Gy of 0.00% and 0.03% (p = 0.013), respectively. Average hippocampi maximum doses were 14.19 ± 1.29 Gy and 15.00 ± 1.51 Gy, respectively. The gamma analysis comparing planned and measured doses resulted in a mean of 99.9% ± 0.12% of passing points (3%/2mm criteria). MRgRT plans had an average of 38.33 beams with average total delivery time and beam-on time of 13.7 (11.2-17.5) min and 4.1 (3.2-5.4) min, respectively. Clinical plan delivery times ranged from 3 to 7 min depending on the number of noncoplanar arcs. Planning time between the clinical and MRgRT plans was comparable.

conclusionThis study demonstrates that HA-WBRT can be treated using an MRI-guided linear accelerator with comparable treatment plan quality and delivery accuracy.

Indexed as

Radiotherapy, Intensity-ModulatedClinical Trials, Phase II as TopicFeasibility StudiesHippocampusHumansMagnetic Resonance ImagingParticle AcceleratorsRadiotherapy DosageRadiotherapy Planning, Computer-AssistedRetrospective StudiesDosimetryHA-WBRTMRI linacTreatment planning

Identifiers

PMID35344266
PMCPMC9195042
OpenAlexW4220733899

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked