Evidence map›Paper›PMID 35342279›Full record

ArticlePhysics of fluids (Woodbury, N.Y. : 1994)2022

Minimizing the COVID-19 spread in hospitals through optimization of ventilation systems.

Hamed Arjmandi, Reza Amini, Mehdi Kashfi, Matthew Alexander Abikenari, Ashkan Davani

Abstract read
In one paragraph

Article in Physics of fluids (Woodbury, N.Y. : 1994), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hamed ArjmandiMR CFD LLC. No 49, Gakhokidze Street, Isani-Samgori District, Tbilisi 0182, Georgia.
Reza AminiMR CFD LLC. No 49, Gakhokidze Street, Isani-Samgori District, Tbilisi 0182, Georgia.ORCID https://orcid.org/0000-0002-9286-6391
Mehdi KashfiMR CFD LLC. No 49, Gakhokidze Street, Isani-Samgori District, Tbilisi 0182, Georgia.
Matthew Alexander AbikenariDepartment of Orthopedic Surgery Research Center, University of California Los Angeles, Los Angeles, California 90095, USA.ORCID https://orcid.org/0000-0001-5835-5179
Ashkan DavaniDepartment of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, California 90007, USA.ORCID https://orcid.org/0000-0003-1853-5794

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The rapid spread of SARS-CoV-2 virus has overwhelmed hospitals with patients in need of intensive care, which is often limited in capacity and is generally reserved for patients with critical conditions. This has led to higher chances of infection being spread to non-COVID-19 patients and healthcare workers and an overall increased probability of cross contamination. The effects of design parameters on the performance of ventilation systems to control the spread of airborne particles in intensive care units are studied numerically. Four different cases are considered, and the spread of particles is studied. Two new criteria for the ventilation system-viz., dimensionless timescale and extraction timescale-are introduced and their performances are compared. Furthermore, an optimization process is performed to understand the effects of design variables (inlet width, velocity, and temperature) on the thermal comfort conditions (predicted mean vote, percentage of people dissatisfied, and air change effectiveness) according to suggested standard values and the relations for calculating these parameters based on the design variables are proposed. Desirability functions that are comprised of all three thermal condition parameters are used to determine the range of variables that result in thermally comfortable conditions and a maximum desirability of 0.865 is obtained. The results show that a poorly designed ventilation system acts like a perfectly stirred reactor-which enormously increases the possibilities of contamination-and that when air is injected from the ceiling and extracted from behind the patient beds, the infection spread is least probable since the particles exit the room orders of magnitude faster.

Identifiers

PMID35342279
PMCPMC8939549

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.