ArticleJournal of magnetic resonance imaging : JMRI2022
Impact of Temporal Resolution and Methods for Correction on Cardiac Magnetic Resonance Perfusion Quantification.
Article in Journal of magnetic resonance imaging : JMRI, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Society for cardiovascular magnetic resonance expert consensus statement on quantitative myocardial perfusion cardiovascular magnetic resonance imaging.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic ResonanceGuideline
- Free-running time-resolved first-pass myocardial perfusion using a multi-scale dynamics decomposition: CMR-MOTUS.Magma (New York, N.Y.) · 2026Article
- High-resolution free-breathing automated quantitative myocardial perfusion by cardiovascular magnetic resonance for the detection of functionally significant coronary artery disease.European heart journal. Cardiovascular Imaging · 2024Article
Corrections and comments
- Commented on by
Authors and funding
3 authors.
Funding
Abstract
backgroundAcquisition of magnetic resonance first-pass perfusion images is synchronized to the patient's heart rate (HR) and governs the temporal resolution. This is inherently linked to the process of myocardial blood flow (MBF) quantification and impacts MBF accuracy but to an unclear extent. PURPOSE: To assess the impact of temporal resolution on quantitative perfusion and compare approaches for accounting for its variability. STUDY TYPE: Prospective phantom and retrospective clinical study. POPULATION AND PHANTOM: Simulations, a cardiac perfusion phantom, and 30 patients with (16, 53%) or without (14, 47%) coronary artery disease. FIELD STRENGTH/SEQUENCE: 3.0 T/2D saturation recovery spoiled gradient echo sequence. ASSESSMENT: Dynamic perfusion data were simulated for a range of reference MBF (1 mL/g/min-5 mL/g/min) and HR (30 bpm-150 bpm). Perfusion imaging was performed in patients and a phantom for different temporal resolutions. MBF and myocardial perfusion reserve (MPR) were quantified without correction for temporal resolution or following correction by either MBF scaling based on the sampling interval or data interpolation prior to quantification. Simulated data were quantified using Fermi deconvolution, truncated singular value decomposition, and one-compartment modeling, whereas phantom and clinical data were quantified using Fermi deconvolution alone. STATISTICAL TESTS: Shapiro-Wilk tests for normality, percentage error (PE) for measuring MBF accuracy in simulations, and one-way repeated measures analysis of variance with Bonferroni correction to compare clinical MBF and MPR. Statistical significance set at P < 0.05.
resultsFor Fermi deconvolution and an example simulated 1 mL/g/min, the MBF PE without correction for temporal resolution was between 55.4% and -62.7% across 30-150 bpm. PE was between -22.2% and -6.8% following MBF scaling and between -14.2% and -14.2% following data interpolation across the same HR. An interpolated HR of 240 bpm reduced PE to ≤10%. Clinical rest and stress MBF and MPR were significantly different between analyses. DATA
conclusionAccurate perfusion quantification needs to account for the variability of temporal resolution, with data interpolation prior to quantification reducing MBF variability across different resolutions. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 1.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.