Evidence map›Paper›PMID 35338574›Full record

ArticleJournal of applied clinical medical physics2022

Retrospective analysis of MV-kV imaging-based fiducial tracking in prostate SBRT treatment.

Kevin Crotteau, Wei Lu, Sean Berry, Laura Happersett, Sarah Burleson, Weixing Cai

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kevin CrotteauDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
Wei LuDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
Sean BerryDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
Laura HappersettDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
Sarah BurlesonDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
Weixing CaiDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI Nicholas D Socci · 1985 to 2026
$347.4M
NCI NIH HHS P30 CA008748
6 · The paper itself

Abstract

purposeMotion management is critical for prostate stereotactic body radiotherapy (SBRT) due to its high fractional dose and proximity to organs at risk. This study seeks to quantify the advantages of MV-kV tracking over kV imaging alone through a retrospective analysis of over 300 patients who underwent prostate SBRT treatment using MV-kV tracking.

methodsAn MV-kV imaging-based fiducial tracking technique has been developed at our institute and become a standard clinical practice. This technique calculates three-dimensional (3D) fiducial displacement in real time from orthogonal kV and MV images acquired simultaneously. The patient will be repositioned if for two consecutive MV-kV data points, the motion is larger than a tolerance of 1.5 mm in any of the lateral, superior-inferior, and/or anterior-posterior directions. This study retrospectively analyzed detected 3D motions using an MV-kV approach of 324 patients who recently underwent prostate SBRT treatments. An algorithm was developed to recover the 2D motion components as if they were detected by kV or MV imaging alone.

resultsOur results indicated that out-of-tolerance motions were primarily limited to the range of 1.5-3 mm (>95%). The motions are primarily anterior-posterior and superior-inferior, with less than 14.8% of the occurrences in the lateral direction. Compared to out-of-tolerance occurrences detected by MV-kV approach, kV alone caught 46.6% of motions in all three directions, and MV alone caught 46.7%. kV alone shows an overall missing rate of 45.8% for superior-inferior motions and 38.6% for lateral motions. It is also demonstrated that the detectability of motion in specific directions greatly depends on gantry angles, as does the missing rate.

conclusionsOur study demonstrated that MV-kV imaging-based intrafraction motion tracking is superior to single kV imaging for prostate SBRT in clinical practice.

Indexed as

RadiosurgeryAlgorithmsFiducial MarkersHumansMaleMovementProstateRadiotherapy Planning, Computer-AssistedRetrospective Studiesfiducial trackingmotion trackingMV-kVprostate SBRT

Identifiers

PMID35338574
PMCPMC9195013

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.