Evidence map›Paper›PMID 35336490›Full record

ArticleSensors (Basel, Switzerland)2022

Low-Cost, Real-Time Polymerase Chain Reaction System for Point-of-Care Medical Diagnosis.

Tchamie Kadja, Chengkun Liu, Yvonne Sun, Vamsy P Chodavarapu

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
1.5field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 19 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Direct Detection ofSensors (Basel, Switzerland) · 2025
    Article
  4. Advances in Cellular and Molecular Biology Assays: A Review of Gold Standard Methods.International journal of innovative science and research technology · 2025
    Article
  5. Review
  6. Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Tchamie KadjaDepartment of Electrical and Computer Engineering, University of Dayton, 300 College Park, Dayton, OH 45469, USA.ORCID 0000-0003-3152-3771
Chengkun LiuDepartment of Electrical and Computer Engineering, University of Dayton, 300 College Park, Dayton, OH 45469, USA.ORCID 0000-0002-1877-8289
Yvonne SunDepartment of Biology, University of Dayton, 300 College Park, Dayton, OH 45469, USA.
Vamsy P ChodavarapuDepartment of Electrical and Computer Engineering, University of Dayton, 300 College Park, Dayton, OH 45469, USA.
University of Dayton · US

Funding

University of Dayton School of Engineering
6 · The paper itself

Abstract

Global health crises due to the prevailing Coronavirus Disease 2019 (COVID-19) pandemic have placed significant strain on health care facilities such as hospitals and clinics around the world. Further, foodborne and waterborne diseases are not only spreading faster, but also appear to be emerging more rapidly than ever before and are able to circumvent conventional control measures. The Polymerase Chain Reaction (PCR) system is a well-known diagnostic tool for many applications in medical diagnostics, environmental monitoring, and food and water quality assessment. Here, we describe the design, development, and testing of a portable, low-cost, and real-time PCR system that can be used in emergency health crises and resource-poor situations. The described PCR system incorporates real-time reaction monitoring using fluorescence as an alternative to gel electrophoresis for reaction analysis, further decreasing the need of multiple reagents, reducing sample testing cost, and reducing sample analysis time. The bill of materials cost of the described system is approximately $340. The described PCR system utilizes a novel progressive selective proportional-integral-derivative controller that helps in reducing sample analysis time. In addition, the system employs a novel primer-based approach to quantify the initial target amplicon concentration, making it well-suited for food and water quality assessment. The developed PCR system performed DNA amplification at a level and speed comparable to larger and more expensive commercial table-top systems. The fluorescence detection sensitivity was also tested to be at the same level as commercially available multi-mode optical readers, thus making the PCR system an attractive solution for medical point-of-care and food and water quality assessment.

Indexed as

COVID-19Point-of-Care SystemsHumansReal-Time Polymerase Chain ReactionCOVID-19fluorescence sensingfood qualitylow-cost PCRpoint-of-care diagnosticspolymerase chain reaction (PCR)proportional–integral–derivative (PID) controllerwater quality

Identifiers

PMID35336490
PMCPMC8955482
OpenAlexW4220700858

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.