Evidence map›Paper›PMID 35336401›Full record

ArticleSensors (Basel, Switzerland)2022

Improving Data Glove Accuracy and Usability Using a Neural Network When Measuring Finger Joint Range of Motion.

James Connolly, Joan Condell, Kevin Curran, Philip Gardiner

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.1field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

James ConnollyLetterkenny Institute of Technology, F92 FC93 Letterkenny, Donegal, Ireland.ORCID 0000-0002-7970-1699
Joan CondellSchool of Computing, Engineering & Intelligent Systems, Ulster University, Londonderry BT48 7JL, UK.ORCID 0000-0002-3517-2182
Kevin CurranSchool of Computing, Engineering & Intelligent Systems, Ulster University, Londonderry BT48 7JL, UK.ORCID 0000-0001-5237-5355
Philip GardinerSchool of Computing, Engineering & Intelligent Systems, Ulster University, Londonderry BT48 7JL, UK.
University of Ulster · GBLetterkenny Institute of Technology · IE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Data gloves capable of measuring finger joint kinematics can provide objective range of motion information useful for clinical hand assessment and rehabilitation. Data glove sensors are strategically placed over specific finger joints to detect movement of the wearers' hand. The construction of the sensors used in a data glove, the number of sensors used, and their positioning on each finger joint are influenced by the intended use case. Although most glove sensors provide reasonably stable linear output, this stability is influenced externally by the physical structure of the data glove sensors, as well as the wearer's hand size relative to the data glove, and the elastic nature of materials used in its construction. Data gloves typically require a complex calibration method before use. Calibration may not be possible when wearers have disabled hands or limited joint flexibility, and so limits those who can use a data glove within a clinical context. This paper examines and describes a unique approach to calibration and angular calculation using a neural network that improves data glove repeatability and accuracy measurements without the requirement for data glove calibration. Results demonstrate an overall improvement in data glove measurements. This is particularly relevant when the data glove is used with those who have limited joint mobility and cannot physically complete data glove calibration.

Indexed as

Finger JointHandBiomechanical PhenomenaNeural Networks, ComputerRange of Motion, Articulardata glovejoint range of motionkinematicsneural networksensor calibration

Identifiers

PMID35336401
PMCPMC8949202
OpenAlexW4220994367

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.