ArticleMolecules (Basel, Switzerland)2022
The Production and Evaluation of an Electrochemical Sensors for Strychnine and Its Main Metabolite Strychnine N-Oxide for Their Use in Biological Samples.
Article in Molecules (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 5 citations in OpenAlex.
- Strychnine poisoning in nontarget species in western Canada: A retrospective case series (2014 to 2023).The Canadian veterinary journal = La revue veterinaire canadienne · 2025Article
- A systematic review of sensors to combat crime and routes to further sensor development.Frontiers in chemistry · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 4 countries.
Funding
Abstract
Strychnine (STN) and its major metabolite Strychnine N-Oxide (SNO) were examined electrochemically. Both parent compounds and its major metabolite showed electroactivity on glassy carbon electrodes using CV and DPV techniques. One oxidation peak at 1008 mV was observed for STN with the optimum peak intensity at pH 7. SNO produced two oxidation peaks, at 617 mV and 797 mV, at pH 5. The peaks demonstrated irreversible behaviour and the irreversibility of the system was confirmed at different scan rates. A calibration curve was produced for both CV and DPV measurements and the sensitivity of the proposed EC method was good compared with previous electrochemical and non-electrochemical methods. The precision of oxidation peak of STN using the STN-MIP method produced a maximum value of 11.5% and 2.32% for inter-day and intraday %RSD, respectively. The average% recovery was around 92%. The electrochemical method has been successfully applied to the determination of STN in spiked plasma and urine samples. For SNO, both anodic peaks of SNO demonstrated irreversible behaviour. A different sweep rate was used for calculating the number of ‘transfer electrons’ in the system; based on this, the mechanism of oxidation reaction was proposed. Calibration curves for both oxidative peaks were produced using DPV measurements. The second anodic peak demonstrated high linearity and precision with %RSD < 1.96%.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.