Evidence map›Paper›PMID 35332646›Full record

ArticleJournal of applied clinical medical physics2022

Dosimetric assessment of patient dose calculation on a deep learning-based synthesized computed tomography image for adaptive radiotherapy.

Olga M Dona Lemus, Yi-Fang Wang, Fiona Li, Sachin Jambawalikar, David P Horowitz, Yuanguang Xu, Cheng-Shie Wuu

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Olga M Dona LemusDepartment of Radiation Oncology, Columbia University Irving Medical Center, New York City, New York, USA.
Yi-Fang WangDepartment of Radiation Oncology, Columbia University Irving Medical Center, New York City, New York, USA.
Fiona LiDepartment of Radiation Oncology, Columbia University Irving Medical Center, New York City, New York, USA.
Sachin JambawalikarDepartment of Radiology, Columbia University Irving Medical Center, New York City, New York, USA.
David P HorowitzDepartment of Radiation Oncology, Columbia University Irving Medical Center, New York City, New York, USA.
Yuanguang XuDepartment of Radiation Oncology, Columbia University Irving Medical Center, New York City, New York, USA.
Cheng-Shie WuuDepartment of Radiation Oncology, Columbia University Irving Medical Center, New York City, New York, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeDose computation using cone beam computed tomography (CBCT) images is inaccurate for the purpose of adaptive treatment planning. The main goal of this study is to assess the dosimetric accuracy of synthetic computed tomography (CT)-based calculation for adaptive planning in the upper abdominal region. We hypothesized that deep learning-based synthetically generated CT images will produce comparable results to a deformed CT (CTdef) in terms of dose calculation, while displaying a more accurate representation of the daily anatomy and therefore superior dosimetric accuracy.

methodsWe have implemented a cycle-consistent generative adversarial networks (CycleGANs) architecture to synthesize CT images from the daily acquired CBCT image with minimal error. CBCT and CT images from 17 liver stereotactic body radiation therapy (SBRT) patients were used to train, test, and validate the algorithm.

resultsThe synthetically generated images showed increased signal-to-noise ratio, contrast resolution, and reduced root mean square error, mean absolute error, noise, and artifact severity. Superior edge matching, sharpness, and preservation of anatomical structures from the CBCT images were observed for the synthetic images when compared to the CTdef registration method. Three verification plans (CBCT, CTdef, and synthetic) were created from the original treatment plan and dose volume histogram (DVH) statistics were calculated. The synthetic-based calculation shows comparatively similar results to the CTdef-based calculation with a maximum mean deviation of 1.5%.

conclusionsOur findings show that CycleGANs can produce reliable synthetic images for the adaptive delivery framework. Dose calculations can be performed on synthetic images with minimal error. Additionally, enhanced image quality should translate into better daily alignment, increasing treatment delivery accuracy.

Indexed as

Deep LearningRadiotherapy Planning, Computer-AssistedCone-Beam Computed TomographyHumansImage Processing, Computer-AssistedRadiotherapy DosageTomography, X-Ray Computeddeep learningdosimetric accuracysynthesized CT

Identifiers

PMID35332646
PMCPMC9278692

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.