Evidence map›Paper›PMID 35330455›Full record

ArticleJournal of personalized medicine2022

Artificial Intelligence-Enabled Electrocardiography Predicts Left Ventricular Dysfunction and Future Cardiovascular Outcomes: A Retrospective Analysis.

Hung-Yi Chen, Chin-Sheng Lin, Wen-Hui Fang, Yu-Sheng Lou, Cheng-Chung Cheng, Chia-Cheng Lee, Chin Lin

2 registry-linked trialsOpen access · goldAbstract read
In one paragraph

Article in Journal of personalized medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 34 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
34citing papers in PubMed, 2 pooled it
6.7field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06699056 recruitingnot on this mapstarted 2024, after this paper: background citation

AI-Enabled Direct-from-ECG Ejection Fraction (EF) Severity Using COR ECG Wearable Monitor

TypeobservationalSponsorPeerbridge Health, IncRan2024 to 2027Enrolled2,000ConditionsVentricular Ejection Fraction, LVF, LV Dysfunction, Atrial EnlargementArms15-minutes of sitting during COR ECG Acquistion
NCT07038018 not yet recruitingnot on this mapstarted 2025, after this paper: background citation

External Validation of Artificial Intelligence-Enabled Electrocardiograms for the Detection of Reduced Left Ventricular Ejection Fraction

TypeobservationalSponsorTri-Service General Hospital (TSGH)Ran2025 to 2025Enrolled12,500ConditionsCardiac DiseaseArmsAI-ECG Algorithm
3 · Its place in the literature

Who cites it

34 citing papers in PubMed, 2 syntheses or guidelines pooled it, 46 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Review
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Hung-Yi ChenDepartment of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei 114, Taiwan.ORCID 0000-0002-8874-6135
Chin-Sheng LinDivision of Cardiology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei 114, Taiwan.ORCID 0000-0002-5167-8327
Wen-Hui FangDepartment of Family and Community Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei 114, Taiwan.
Yu-Sheng LouGraduate Institute of Life Sciences, National Defense Medical Center, Taipei 114, Taiwan.
Cheng-Chung ChengDivision of Cardiology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei 114, Taiwan.
Chia-Cheng LeePlanning and Management Office, Tri-Service General Hospital, National Defense Medical Center, Taipei 114, Taiwan.
Chin LinGraduate Institute of Life Sciences, National Defense Medical Center, Taipei 114, Taiwan.ORCID 0000-0003-2337-2096
Tri-Service General Hospital · TW

Funding

Ministry of Science and Technology MOST 108-2314-B-016-001Ministry of Science and Technology MOST 108-3111-Y-016-009Ministry of Science and Technology MOST 109-2314-B-016-026Ministry of Science and Technology MOST 109-3111-Y-016-002Ministry of Science and Technology MOST 110-2314-B-016-010-MY3Ministry of Science and Technology MOST 110-3111-Y-016-005
6 · The paper itself

Abstract

backgroundThe ejection fraction (EF) provides critical information about heart failure (HF) and its management. Electrocardiography (ECG) is a noninvasive screening tool for cardiac electrophysiological activities that has been used to detect patients with low EF based on a deep learning model (DLM) trained via large amounts of data. However, no studies have widely investigated its clinical impacts.

objectiveThis study developed a DLM to estimate EF via ECG (ECG-EF). We further investigated the relationship between ECG-EF and echo-based EF (ECHO-EF) and explored their contributions to future cardiovascular adverse events.

methodsThere were 57,206 ECGs with corresponding echocardiograms used to train our DLM. We compared a series of training strategies and selected the best DLM. The architecture of the DLM was based on ECG12Net, developed previously. Next, 10,762 ECGs were used for validation, and another 20,629 ECGs were employed to conduct the accuracy test. The changes between ECG-EF and ECHO-EF were evaluated. The primary follow-up adverse events included future ECHO-EF changes and major adverse cardiovascular events (MACEs).

resultsThe sex-/age-matching strategy-trained DLM achieved the best area under the curve (AUC) of 0.9472 with a sensitivity of 86.9% and specificity of 89.6% in the follow-up cohort, with a correlation of 0.603 and a mean absolute error of 7.436. In patients with accurate prediction (initial difference < 10%), the change traces of ECG-EF and ECHO-EF were more consistent (R-square = 0.351) than in all patients (R-square = 0.115). Patients with lower ECG-EF (≤35%) exhibited a greater risk of cardiovascular (CV) complications, delayed ECHO-EF recovery, and earlier ECHO-EF deterioration than patients with normal ECG-EF (>50%). Importantly, ECG-EF demonstrated an independent impact on MACEs and all CV adverse outcomes, with better prediction of CV outcomes than ECHO-EF.

conclusionsThe ECG-EF could be used to initially screen asymptomatic left ventricular dysfunction (LVD) and it could also independently contribute to the predictions of future CV adverse events. Although further large-scale studies are warranted, DLM-based ECG-EF could serve as a promising diagnostic supportive and management-guided tool for CV disease prediction and the care of patients with LVD.

Indexed as

artificial intelligencecardiovascular diseasedeep learningejection fractionelectrocardiogramheart failure

Identifiers

PMID35330455
PMCPMC8950054
OpenAlexW4221130039

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.