ArticleJournal of personalized medicine2022
Artificial Intelligence-Enabled Electrocardiography Predicts Left Ventricular Dysfunction and Future Cardiovascular Outcomes: A Retrospective Analysis.
Article in Journal of personalized medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 34 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
AI-Enabled Direct-from-ECG Ejection Fraction (EF) Severity Using COR ECG Wearable Monitor
External Validation of Artificial Intelligence-Enabled Electrocardiograms for the Detection of Reduced Left Ventricular Ejection Fraction
Who cites it
34 citing papers in PubMed, 2 syntheses or guidelines pooled it, 46 citations in OpenAlex.
- Deep learning and electrocardiography: systematic review of current techniques in cardiovascular disease diagnosis and management.Biomedical engineering online · 2025Pooled it
- Artificial intelligence enabled ECG screening for left ventricular systolic dysfunction: a systematic review.Heart failure reviews · 2023Pooled it
- Trial
- Bridging the gap from clinical to home ECG: quantifying and overcoming accuracy loss in AI-enabled single-lead ECG models.NPJ digital medicine · 2026Article
- AI-Powered Resting 12-Lead Electrocardiogram Algorithm for Predicting Low Peak Oxygen Consumption: Development and Validation Study.JMIR medical informatics · 2026Article
- Discriminating HFrEF vs HFpEF from chest radiographs: Mitigating demographic performance gaps via augmentation and multimodal fusion.PLOS digital health · 2026Article
- Personalized artificial intelligence based left ventricular ejection fraction and systolic dysfunction assessment.NPJ digital medicine · 2026Article
- Development and temporal validation of a two-stage ECG-based machine learning model for LVEF screening: a Middle Eastern cohort study.BMC cardiovascular disorders · 2026Article
- Non-invasive hemoglobin estimation with outcome prediction via deep learning analysis of ECG-derived cardiac micro-dynamics.Internal and emergency medicine · 2026Article
- Web-Based Application of Simplified Machine Learning for Detecting Reduced LVEF From 12-Lead ECG.Journal of arrhythmia · 2026Article
- Artificial intelligence-enabled electrocardiography from scientific research to clinical application.EMBO molecular medicine · 2026Review
- The Narrative Review: Advancements in Heart Failure Diagnosis and Management using Artificial Intelligence: A New Era of Patient Care.Current cardiology reviews · 2026Review
- Artificial Intelligence-Enabled Electrocardiography Identifies Osteoporosis and has Prognostic Value.Journal of medical systems · 2025Article
- Estimating LVEF from ECG with GPT-4o Fine-Tuned Vision: A Novel Approach in AI-Driven Cardiac Diagnostics.Journal of medical systems · 2025Article
- Prognostic Significance of AI-Enhanced ECG for Emergency Department Patients.Diagnostics (Basel, Switzerland) · 2025Article
- Artificial intelligence in ECG-based diagnosis of low left ventricular ejection fraction: a systematic review and meta-analysis.Biomedical engineering letters · 2025Review
- Economic analysis of an AI-enabled ECG alert system: impact on mortality outcomes from a pragmatic randomized trial.NPJ digital medicine · 2025Article
- Cardiovascular Risk Assessment via Sleep Patterns and ECG-Based Biological Age Estimation.Journal of clinical medicine · 2025Article
- Artificial intelligence-enhanced six-lead portable electrocardiogram device for detecting left ventricular systolic dysfunction: a prospective single-centre cohort study.European heart journal. Digital health · 2025Article
- AI analysis for ejection fraction estimation from 12-lead ECG.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
Abstract
backgroundThe ejection fraction (EF) provides critical information about heart failure (HF) and its management. Electrocardiography (ECG) is a noninvasive screening tool for cardiac electrophysiological activities that has been used to detect patients with low EF based on a deep learning model (DLM) trained via large amounts of data. However, no studies have widely investigated its clinical impacts.
objectiveThis study developed a DLM to estimate EF via ECG (ECG-EF). We further investigated the relationship between ECG-EF and echo-based EF (ECHO-EF) and explored their contributions to future cardiovascular adverse events.
methodsThere were 57,206 ECGs with corresponding echocardiograms used to train our DLM. We compared a series of training strategies and selected the best DLM. The architecture of the DLM was based on ECG12Net, developed previously. Next, 10,762 ECGs were used for validation, and another 20,629 ECGs were employed to conduct the accuracy test. The changes between ECG-EF and ECHO-EF were evaluated. The primary follow-up adverse events included future ECHO-EF changes and major adverse cardiovascular events (MACEs).
resultsThe sex-/age-matching strategy-trained DLM achieved the best area under the curve (AUC) of 0.9472 with a sensitivity of 86.9% and specificity of 89.6% in the follow-up cohort, with a correlation of 0.603 and a mean absolute error of 7.436. In patients with accurate prediction (initial difference < 10%), the change traces of ECG-EF and ECHO-EF were more consistent (R-square = 0.351) than in all patients (R-square = 0.115). Patients with lower ECG-EF (≤35%) exhibited a greater risk of cardiovascular (CV) complications, delayed ECHO-EF recovery, and earlier ECHO-EF deterioration than patients with normal ECG-EF (>50%). Importantly, ECG-EF demonstrated an independent impact on MACEs and all CV adverse outcomes, with better prediction of CV outcomes than ECHO-EF.
conclusionsThe ECG-EF could be used to initially screen asymptomatic left ventricular dysfunction (LVD) and it could also independently contribute to the predictions of future CV adverse events. Although further large-scale studies are warranted, DLM-based ECG-EF could serve as a promising diagnostic supportive and management-guided tool for CV disease prediction and the care of patients with LVD.