Evidence map›Paper›PMID 35329077›Full record

ArticleInternational journal of environmental research and public health2022

Factors Associated with Polyp Detection Rate in European Colonoscopy Practice: Findings of The European Colonoscopy Quality Investigation (ECQI) Group.

Cristiano Spada, Anastasios Koulaouzidis, Cesare Hassan, Pedro Amaro, Anurag Agrawal, Lene Brink, Wolfgang Fischbach, Matthias Hünger, Rodrigo Jover, Urpo Kinnunen and 11 more

Open access · goldAbstract read
In one paragraph

Article in International journal of environmental research and public health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

21 authors at 16 institutions in 10 countries.

Cristiano SpadaDigestive Endoscopy Unit and Gastroenterology, Fondazione Poliambulanza, 25124 Brescia, Italy.
Anastasios KoulaouzidisDepartment of Medicine, OUH Svendborg Sygehus, 5700 Svendborg, Denmark.ORCID 0000-0002-2248-489X
Cesare HassanEndoscopy Unit, IRCCS Humanitas Clinical and Research Center, 20089 Milan, Italy.
Pedro AmaroGastroenterology Department, Centro Hospitalar e Universitário de Coimbra, 3000-075 Coimbra, Portugal.
Anurag AgrawalGastroenterology, Doncaster Royal Infirmary, Doncaster DN2 5LT, UK.
Lene BrinkGastro Unit, Division of Endoscopy, Herlev and Gentofte Hospital, Copenhagen University, 2730 Herlev, Denmark.
Wolfgang FischbachGastroenterologie und Innere Medizin, 63739 Aschaffenburg, Germany.
Matthias HüngerIndependent Researcher for Internal Medicine, 97070 Würzburg, Germany.
Rodrigo JoverInstituto de Investigación Sanitaria ISABIAL-Servicio de Medicina Digestiva, Hospital General Universitario de Alicante, 03010 Alicante, Spain.
Urpo KinnunenDepartment of Gastroenterology, Tampere University Hospital, 33521 Tampere, Finland.ORCID 0000-0003-2299-0028
Akiko OnoDepartment of Gastroenterology, Hospital Clínico Universitario Virgen de la Arrixaca, 30120 Murcia, Spain.
Árpád PataiDepartment of Gastroenterology and Medicine, Markusovszky University Teaching Hospital, 9700 Szombathely, Hungary.
Silvia PecereDigestive Endoscopy Unit, Università Cattolica del Sacro Cuore, 00168 Rome, Italy.ORCID 0000-0002-4401-7344
Lucio PetruzzielloDigestive Endoscopy Unit, Università Cattolica del Sacro Cuore, 00168 Rome, Italy.
Jürgen Ferdinand RiemannDepartment of Medicine C, Klinikum Ludwigshafen, 67063 Ludwigshafen, Germany.
Harry StainesSigma Statistical Services Ltd., Saint Andrews KY16 0BD, UK.ORCID 0000-0003-1135-5221
Ann L StringerECQI Secretariat, Buckinghamshire HP17 8ET, UK.
Ervin TothDepartment of Gastroenterology, Skåne University Hospital, Lund University, 205 02 Malmö, Sweden.ORCID 0000-0002-9314-9239
Giulio AntonelliDepartment of Anatomical, Histological, Forensic Medicine and Orthopedics Sciences, Sapienza University of Rome, 00185 Rome, Italy.
Lorenzo FuccioGastroenterology Unit, Department of Medical and Surgical Sciences, S.Orsola-Malpighi Hospital, 40138 Bologna, Italy.
On Behalf Of The Ecqi Group
Università Cattolica del Sacro Cuore · ITDoncaster Royal Infirmary · GBGentofte Hospital · DKHospitais da Universidade de Coimbra · PTHospital General Universitario de Alicante Doctor Balmis · ESHospital Universitario Virgen de la Arrixaca · ESHumanitas University · ITIRCCS Azienda Ospedliero-Universitaria di Bologna Policlinico di Sant'Orsola · ITKlinikum Aschaffenburg · DEKlinikum Ludwigshafen · DELund University · SEMarkusovszky Egyetemi Oktatókórház · HURoyal Statistical Society · GBSapienza University of Rome · ITTampere University Hospital · FIUniversity of Southern Denmark · DK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The European Colonoscopy Quality Investigation (ECQI) Group aims to raise awareness for improvement in colonoscopy standards across Europe. We analysed data collected on a sample of procedures conducted across Europe to evaluate the achievement of the polyp detection rate (PDR) target. We also investigated factors associated with PDR, in the hope of establishing areas that could lead to a quality improvement. Methods: 6445 form completions from 12 countries between 2 June 2016 and 30 April 2018 were considered for this analysis. We performed an exploratory analysis looking at PDR according to European Society of Gastrointestinal Endoscopy (ESGE) definition. Stepwise multivariable logistic regression analysis was conducted to determine the most influential associated factors after adjusting for the other pre-specified variables. Results: In our sample there were 3365 screening and diagnostic procedures performed in those over 50 years. The PDR was 40.5%, which is comparable with the ESGE minimum standard of 40%. The variables found to be associated with PDR were in descending order: use of high-definition equipment, body mass index (BMI), patient gender, age group, and the reason for the procedure. Use of HD equipment was associated with a significant increase in the reporting of flat lesions (14.3% vs. 5.7%, p < 0.0001) and protruded lesions (34.7% vs. 25.4%, p < 0.0001). Conclusions: On average, the sample of European practice captured by the ECQI survey meets the minimum PDR standard set by the ESGE. Our findings support the ESGE recommendation for routine use of HD colonoscopy.

Indexed as

Colonic PolypsColorectal NeoplasmsColonoscopyEndoscopy, GastrointestinalHumansMass ScreeningQuality Improvementcolonoscopycolonoscopy standardspolyp detection ratequality measuressurvey

Identifiers

PMID35329077
PMCPMC8954761
OpenAlexW4221133466

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.