Evidence map›Paper›PMID 35328891›Full record

ArticleInternational journal of environmental research and public health2022

A Novel Digital Technique to Analyze the Wear of CM-Wire NiTi Alloy Endodontic Reciprocating Files: An In Vitro Study.

Vicente Faus-Matoses, Vicente Faus-Llácer, Álvaro Aldeguer Muñoz, Jorge Alonso Pérez-Barquero, Ignacio Faus-Matoses, Celia Ruiz-Sánchez, Álvaro Zubizarreta-Macho

Abstract read
In one paragraph

Article in International journal of environmental research and public health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Accuracy of Endodontic Access Cavities Performed Using an Augmented Reality Appliance: An In Vitro Study.International journal of environmental research and public health · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Vicente Faus-MatosesDepartment of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.ORCID 0000-0003-2452-4135
Vicente Faus-LlácerDepartment of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.ORCID 0000-0002-2507-4132
Álvaro Aldeguer MuñozDepartment of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.
Jorge Alonso Pérez-BarqueroDepartment of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.ORCID 0000-0002-7275-0199
Ignacio Faus-MatosesDepartment of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.
Celia Ruiz-SánchezDepartment of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.
Álvaro Zubizarreta-MachoDepartment of Endodontics, Faculty of Health Sciences, Alfonso X El Sabio University, 28691 Madrid, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The present study seeks to describe a novel digital measurement technique for analyzing the wear volume of controlled memory (CM)-wire NiTi alloy endodontic reciprocating files after clinical use. MATERIAL AND

methodsTen CM-wire NiTi endodontic reciprocating files were randomly used in ten first upper molar teeth within four root canals. The CM-wire NiTi alloy endodontic reciprocating files were subjected to preoperative and postoperative micro-computed tomography (micro-CT) scans to obtain accurate digital imaging and communication on medicine (DICOM) digital files, which were segmented using intensity-based thresholding and an exclusive OR (XOR) logical operation (Boolean algebra logical operator) to obtain a mask of the location to localize and quantify the wear volume of the CM-wire NiTi alloy endodontic reciprocating files. Gage repeatability and reproducibility statistical analysis was applied to assess the reproducibility and repeatability of this measurement technique.

resultsThe analysis showed a repeatability and reproducibility of 0.00% for the digital measurement technique used to analyze the wear volume of CM-wire NiTi alloy endodontic reciprocating files after clinical use. Wear was mostly identified at the tip and cutting edges of the CM-wire NiTi alloy endodontic reciprocating files.

conclusionsThis novel digital measurement technique is a repeatable, reproducible, and accurate method of quantifying the wear volume of CM-wire NiTi alloy endodontic reciprocating files after clinical use.

Indexed as

AlloysRoot Canal PreparationEquipment DesignReproducibility of ResultsTitaniumX-Ray MicrotomographyAlloysTitaniumcyclic fatigueendodonticsmicro-computed tomographyNiTireciprocating movementwear

Identifiers

PMID35328891
PMCPMC8951034

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.