Evidence map›Paper›PMID 35323411›Full record

ArticleBiosensors2022

Compact Surface Plasmon Resonance IgG Sensor Based on H-Shaped Optical Fiber.

Yijian Huang, Ying Wang, Gaixia Xu, Xing Rao, Jiaxiong Zhang, Xun Wu, Changrui Liao, Yiping Wang

Abstract read
In one paragraph

Article in Biosensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. L-cysteine/MoSScientific reports · 2023
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yijian HuangKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.ORCID 0000-0003-4337-956X
Ying WangKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
Gaixia XuGuangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Shenzhen University Health Science Center, Shenzhen 518060, China.
Xing RaoKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
Jiaxiong ZhangKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
Xun WuKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
Changrui LiaoKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
Yiping WangKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.ORCID 0000-0002-7730-8906

Funding

National Natural Science Foundation of China 61675137 ; 61905166Science and Technology Innovation Commission of Shenzhen JCYJ20170818093743767; JCYJ20180507183904841
6 · The paper itself

Abstract

A compact surface plasmon resonance sensor based on an H-shaped optical fiber is proposed and demonstrated. The H-shaped optical fiber was fabricated experimentally by using hydrofluoric acid to controllably corrode the polarization-maintaining fiber. A satisfactory distance between the outer surface of the fiber and the core can be achieved, and then the surface plasmon resonance effect can be excited by coating a metal film of appropriate thickness on the surface of the fiber. This technology can realize the preparation of multiple samples at one time, compared to the traditional side-polishing technique. The H-shaped optical fiber obtained from corrosion exhibits a high surface quality and short lengths, down to only a few hundred microns. The effects of the proposed H-shaped optical fiber on spectral properties are induced by process parameters, including fiber remaining thickness, coating thickness and fiber length, and were investigated in detail. The prepared sensor was used for the specific detection of human IgG, and the minimum human IgG concentration that the sensor can distinguish is 3.4 μg/mL. Such a compact surface plasmon resonance fiber sensor has the advantages of an easy fabrication, good consistency and low cost, and is expected to be applied in the specific detection of biomarkers.

Indexed as

Optical FibersSurface Plasmon ResonanceHumansImmunoglobulin GImmunoglobulin Gbiosensorchemical corrosionpolarization-maintaining fibersurface plasmon resonance

Identifiers

PMID35323411
PMCPMC8946733

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.