Biomechanical effect of metal augment and bone graft on cup stability for acetabular reconstruction of total hip arthroplasty in hip dysplasia: a finite element analysis.

Yuzhu Wang, Mincong Wang, Chengguo Li, Yoshihiro Nakamura, Liwei Deng, Go Yamako, Etsuo Chosa, Chenglong Pan

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
3.3field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Observational
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Yuzhu WangDepartment of Orthopaedic Surgery, The Fifth Affiliated Hospital of Southern Medical University, Guangzhou, Guangdong, China.
Mincong WangDepartment of Orthopaedic Surgery, The Fifth Affiliated Hospital of Southern Medical University, Guangzhou, Guangdong, China.
Chengguo LiDepartment of Orthopaedic Surgery, The Fifth Affiliated Hospital of Southern Medical University, Guangzhou, Guangdong, China.
Yoshihiro NakamuraDepartment of Orthopaedic Surgery, Faculty of Medicine, University of Miyazaki, Miyazaki, Miyazaki, Japan.
Liwei DengDepartment of Radiology, The Fifth Affiliated Hospital of Southern Medical University, Guangzhou, Guangdong, China.
Go YamakoDepartment of Mechanical Engineering, Faculty of Engineering, University of Miyazaki, Miyazaki, Miyazaki, Japan.
Etsuo ChosaDepartment of Orthopaedic Surgery, Faculty of Medicine, University of Miyazaki, Miyazaki, Miyazaki, Japan.
Chenglong PanDepartment of Orthopaedic Surgery, The Fifth Affiliated Hospital of Southern Medical University, Guangzhou, Guangdong, China. pclgjwk@163.com.
Third Affiliated Hospital of Southern Medical University · CNUniversity of Miyazaki · JPSouthern Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDifferent methods of acetabular reconstruction with total hip arthroplasty (THA) for Crowe II and III of adult developmental dysplasia of the hip (DDH) acetabular bone defect have been implemented clinically. However, the biomechanical effect of different augmented materials for acetabular reconstruction in THA on shell stability has never been discussed.

methodsIn the present study, autologous bone graft (BG)and metal (Ti6Al4V) augment (MA) were simulated with several acetabular bone defect models of DDH in THA. The contact pressure and micromotion between the shell and host bone were measured for evaluating the shell stability using a finite element method.

resultsThe peak contact stress between shell and host bone was higher in the MA situation (12.45 vs 8.71 MPa). And the load transfer path was different, for BG models, the high local contact stresses were found at the junction of bone graft and host bone while for MA models the concentrated contact stresses were at the surface of MA. The peak relative micromotion between shell and host bone was higher in the MA situation (12.61 vs 11.13 µm). However, the peak micromotion decreased in the contact interface of MA and cup compared to the BG models.

conclusionsThe higher micromotion was found in MA models, however, enough for bone ingrowth, and direct stronger fixation was achieved in the MA-cup interface. Thus, we recommended the MA can be used as an option, even for Crowe III, however, the decision should be made from clinical follow-up results.

Indexed as

Arthroplasty, Replacement, HipHip DislocationHip ProsthesisAcetabulumAdultFinite Element AnalysisHumansAcetabular reconstructionAugmentCup stabilityFinite element analysis

Identifiers

PMID35321681
PMCPMC8943934
OpenAlexW4221122918

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.