ArticleScience advances2022
Wearable plasmonic paper-based microfluidics for continuous sweat analysis.
Article in Science advances, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 65 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
65 citing papers in PubMed.
- Microfluidic valves for wearable sweat analysis: a review.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2026Review
- Self-Powered Triboelectric Biofluid Sensors for Early Disease Screening and Diagnosis: A Review.Nanomaterials (Basel, Switzerland) · 2026Review
- AI-Ready Multimodal Wearable Biosensors Beyond Glucose: Biofluid Sampling, Sensor Fusion, and Clinical Translation.Biosensors · 2026Review
- Regulating the Nano-Bio Interface: Converging Electrochemical and Photonic Biosensing for Wearable Diagnostics.Nano letters · 2026Review
- Integrated microfluidic biosensors: shaping the future of quantitative life sciences and on-chip molecular diagnostics.Lab on a chip · 2026Review
- Ultrasound-enabled refreshable electrochemical sensors for cardiac biomarker monitoring.Biosensors & bioelectronics · 2026Article
- Making Sweat Measurable: Induction, Sampling, and Refreshment in Wearable Biofluid Sensing.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Review
- Machine learning-assisted wearable SERS-microfluidic system for rapid detection of sweat biomarkers and stimulants.Analytical and bioanalytical chemistry · 2026Article
- Miniaturisation of Raman spectroscopy systems: from benchtop to backpocket.Lab on a chip · 2026Review
- Paper-based microfluidics for wearable soft bioelectronics.Lab on a chip · 2026Review
- Morphology-adaptive Au-Ag nanowire elastronics for integrated FlexoSERS and bioelectrical sensing.Science advances · 2026Article
- Carbon Nanotube-Induced Enzyme Polymerization for Wearable Multifunctional Biosensors in Sweat Analysis.JACS Au · 2026Article
- Meta-amplified dark-field interferometric scattering microscopy.Nature communications · 2026Article
- Recent Advances in Reactive Microdroplets for Clean Water and Energy.Advanced materials (Deerfield Beach, Fla.) · 2025Review
- Photonic Nanomaterials for Wearable Health Solutions.Advanced materials (Deerfield Beach, Fla.) · 2025Review
- SERS Cheminformatics: Opportunities for Data-Driven Discovery and Applications.ACS central science · 2025Review
- A highly sensitive and multiplexed wireless sensing system with skin-like compliance and stretchability for wearable applications.Science advances · 2025Article
- Review
- Microfluidic technologies for wearable and implantable biomedical devices.Lab on a chip · 2025Review
- Advancements and Future Perspectives of Microfluidic Technology in Pediatric Healthcare.Smart medicine · 2025Review
5 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Wearable sweat sensors have the potential to provide clinically meaningful information associated with the health and disease states of individuals. Current sensors mainly rely on enzymes and antibodies as biorecognition elements to achieve specific quantification of metabolite and stress biomarkers in sweat. However, enzymes and antibodies are prone to degrade over time, compromising the sensor performance. Here, we introduce a wearable plasmonic paper-based microfluidic system for continuous and simultaneous quantitative analysis of sweat loss, sweat rate, and metabolites in sweat. Plasmonic sensors based on label-free surface-enhanced Raman spectroscopy (SERS) can provide chemical "fingerprint" information for analyte identification. We demonstrate the sensitive detection and quantification of uric acid in sweat at physiological and pathological concentrations. The well-defined flow characteristics of paper microfluidic devices enable accurate quantification of sweat loss and sweat rate. The wearable plasmonic device is soft, flexible, and stretchable, which can robustly interface with the skin without inducing chemical or physical irritation.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.