Evidence map›Paper›PMID 35319784›Full record

ArticleMedical physics2022

Finite element analysis of trabecular bone microstructure using CT imaging and continuum mechanical modeling.

Indranil Guha, Xiaoliu Zhang, Chamith S Rajapakse, Gregory Chang, Punam K Saha

Open access · hybridAbstract read
In one paragraph

Article in Medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
4.6field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Novel CT-based vertebral three-dimensional Hounsfield unit for assessment of bone mineral density.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Continuum finite element analysis generalizesBiomedical physics & engineering express · 2023
    Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Indranil GuhaDepartment of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, Iowa, USA.
Xiaoliu ZhangDepartment of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, Iowa, USA.
Chamith S RajapakseDepartments of Radiology and Orthopaedic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Gregory ChangDepartment of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
Punam K SahaDepartment of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, Iowa, USA.
University of Iowa · USNew York University · USUniversity of Pennsylvania · US

Funding

CT-Based Modeling of Bone Micro-Architecture and Fracture-Risk in COPDR01HL142042 · NHLBI · UNIVERSITY OF IOWA · PI SAHA, PUNAM K. · 2018 to 2022
$3.5M
NHLBI NIH HHS R01 HL142042NIH HHS R01 HL142042
6 · The paper itself

Abstract

purposeOsteoporosis is a bone disease associated with enhanced bone loss, microstructural degeneration, and fracture-risk. Finite element (FE) modeling is used to estimate trabecular bone (Tb) modulus from high-resolution three-dimensional (3-D) imaging modalities including micro-computed tomography (CT), magnetic resonance imaging (MRI), and high-resolution peripheral quantitative CT (HR-pQCT). This paper validates an application of voxel-based continuum finite element analysis (FEA) to predict Tb modulus from clinical CT imaging under a condition similar to in vivo imaging by comparing with measures derived by micro-CT and experimental approaches.

methodVoxel-based continuum FEA methods for CT imaging were implemented using linear and nonlinear models and applied on distal tibial scans under a condition similar to in vivo imaging. First, tibial axis in a CT scan was aligned with the coordinate z-axis at 150 μm isotropic voxels. FEA was applied on an upright cylindrical volume of interests (VOI) with its axis coinciding with the tibial bone axis. Voxel volume, edge, and vertex elements and their connectivity were defined as per the isotropic image grid. A calibration phantom was used to calibrate CT numbers in Hounsfield unit to bone mineral density (BMD) values, which was then converted into calcium hydroxyapatite (CHA) density. Mechanical properties at each voxel volume element was defined using its ash-density defined on CT-derived CHA density. For FEA, the bottom surface of the cylindrical VOI was fixed and a constant displacement was applied along the z-direction at each vertex element on the top surface to simulate a physical axial compressive loading condition. Finally, a Poisson's ratio of 0.3 was applied, and Tb modulus (MPa) was computed as the ratio of average von Mises stress (MPa) of volume elements on the top surface and the applied displacement. FEA parameters including mesh element size, substep number, and different tolerance values were optimized.

resultsCT-derived Tb modulus values using continuum FEA showed high linear correlation with the micro-CT-derived reference values (r ∈ [0.87 0.90]) as well as experimentally measured values (r ∈ [0.80 0.87]). Linear correlation of computed modulus with their reference values using continuum FEA with linear modeling was comparable with that obtained by nonlinear modeling. Nonlinear continuum FEA-based modulus values (mean of 1087.2 MPa) showed greater difference from their reference values (mean of 1498.9 MPa using micro-CT-based FEA) as compared with linear continuum methods. High repeat CT scan reproducibility (intra-class correlation [ICC] = 0.98) was observed for computed modulus values using both linear and nonlinear continuum FEA. It was observed that high stress regions coincide with Tb microstructure as fuzzily characterized by BMD values. Distributions of von Mises stress over Tb microstructure and marrow regions were significantly different (p < 10

conclusionVoxel-based continuum FEA offers surrogate measures of Tb modulus from CT imaging under a condition similar to in vivo imaging that alleviates the need for segmentation of Tb and marrow regions, while accounting for bone distribution at the microstructural level. This relaxation of binary segmentation will extend the scope of FEA application to assess mechanical properties of bone microstructure at relatively low-resolution imaging.

Indexed as

Cancellous BoneTibiaBone DensityFinite Element AnalysisReproducibility of ResultsX-Ray MicrotomographyANSYS softwareash densitycontinuum FEACT imaginglinear and nonlinear modelingmicrostructuremodulusosteoporosistrabecular bonevon Mises stress

Identifiers

PMID35319784
PMCPMC9325403
OpenAlexW4221086415

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.