ArticleMedical physics2022
Finite element analysis of trabecular bone microstructure using CT imaging and continuum mechanical modeling.
Article in Medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 27 citations in OpenAlex.
- Biomechanical comparison of mini-plate and screw fixation in minimally invasive distal metatarsal osteotomy for hallux valgus : a finite element and cadaveric study.Bone & joint research · 2026Article
- Article
- Comparative Molecular Insights and Computational Modeling of Multiple Myeloma and Osteosarcoma.International journal of molecular sciences · 2026Review
- Development and clinical application of a high-performance medical static computed tomography system.Journal of applied clinical medical physics · 2026Article
- Novel CT-based vertebral three-dimensional Hounsfield unit for assessment of bone mineral density.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025Article
- High-Intensity Physical Activity During Late Adolescence Predicts Young Adult CT-Based Finite Element Bone Strength in Emerging Adulthood: Iowa Bone Development Study.Children (Basel, Switzerland) · 2025Article
- High-resolution peripheral quantitative computed tomography reliability and accuracy of bone density and morphology properties in children.JBMR plus · 2025Article
- Age-related traumatic anatomy and personalized medial incision design for calcaneal fractures in older adults using three-dimensional mapping.Journal of orthopaedic surgery and research · 2025Article
- Producing micro-finite element models from real-time clinical CT scanners: calibration, validation and material mapping strategies.Frontiers in bioengineering and biotechnology · 2025Article
- Ultra-low dose hip CT-based automated measurement of volumetric bone mineral density at proximal femoral subregions.Medical physics · 2024Article
- Deep learning-based harmonization of trabecular bone microstructures between high- and low-resolution CT imaging.Medical physics · 2024Article
- Preserving Trabecular Bone Structure in Gross Specimens with Paraffin Wax for the Study of Osteoporosis.Journal of plastination · 2024Article
- Characterization of mechanical stiffness using additive manufacturing and finite element analysis: potential tool for bone health assessment.3D printing in medicine · 2023Article
- Mechanical Biomarkers in Bone Using Image-Based Finite Element Analysis.Current osteoporosis reports · 2023Review
- Continuum finite element analysis generalizesBiomedical physics & engineering express · 2023Article
- Finite element analysis of trabecular bone microstructure using CT imaging and continuum mechanical modeling.Medical physics · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
Abstract
purposeOsteoporosis is a bone disease associated with enhanced bone loss, microstructural degeneration, and fracture-risk. Finite element (FE) modeling is used to estimate trabecular bone (Tb) modulus from high-resolution three-dimensional (3-D) imaging modalities including micro-computed tomography (CT), magnetic resonance imaging (MRI), and high-resolution peripheral quantitative CT (HR-pQCT). This paper validates an application of voxel-based continuum finite element analysis (FEA) to predict Tb modulus from clinical CT imaging under a condition similar to in vivo imaging by comparing with measures derived by micro-CT and experimental approaches.
methodVoxel-based continuum FEA methods for CT imaging were implemented using linear and nonlinear models and applied on distal tibial scans under a condition similar to in vivo imaging. First, tibial axis in a CT scan was aligned with the coordinate z-axis at 150 μm isotropic voxels. FEA was applied on an upright cylindrical volume of interests (VOI) with its axis coinciding with the tibial bone axis. Voxel volume, edge, and vertex elements and their connectivity were defined as per the isotropic image grid. A calibration phantom was used to calibrate CT numbers in Hounsfield unit to bone mineral density (BMD) values, which was then converted into calcium hydroxyapatite (CHA) density. Mechanical properties at each voxel volume element was defined using its ash-density defined on CT-derived CHA density. For FEA, the bottom surface of the cylindrical VOI was fixed and a constant displacement was applied along the z-direction at each vertex element on the top surface to simulate a physical axial compressive loading condition. Finally, a Poisson's ratio of 0.3 was applied, and Tb modulus (MPa) was computed as the ratio of average von Mises stress (MPa) of volume elements on the top surface and the applied displacement. FEA parameters including mesh element size, substep number, and different tolerance values were optimized.
resultsCT-derived Tb modulus values using continuum FEA showed high linear correlation with the micro-CT-derived reference values (r ∈ [0.87 0.90]) as well as experimentally measured values (r ∈ [0.80 0.87]). Linear correlation of computed modulus with their reference values using continuum FEA with linear modeling was comparable with that obtained by nonlinear modeling. Nonlinear continuum FEA-based modulus values (mean of 1087.2 MPa) showed greater difference from their reference values (mean of 1498.9 MPa using micro-CT-based FEA) as compared with linear continuum methods. High repeat CT scan reproducibility (intra-class correlation [ICC] = 0.98) was observed for computed modulus values using both linear and nonlinear continuum FEA. It was observed that high stress regions coincide with Tb microstructure as fuzzily characterized by BMD values. Distributions of von Mises stress over Tb microstructure and marrow regions were significantly different (p < 10
conclusionVoxel-based continuum FEA offers surrogate measures of Tb modulus from CT imaging under a condition similar to in vivo imaging that alleviates the need for segmentation of Tb and marrow regions, while accounting for bone distribution at the microstructural level. This relaxation of binary segmentation will extend the scope of FEA application to assess mechanical properties of bone microstructure at relatively low-resolution imaging.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.