ArticleMedical physics2022
Addressing CT metal artifacts using photon-counting detectors and one-step spectral CT image reconstruction.
Article in Medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 29 citations in OpenAlex.
- Experimental investigation of metal artifact reduction using one-step spectral CT reconstruction.Medical physics · 2026Article
- Application of streak metal artifact reduction technique in cone-beam computed tomography guided percutaneous transthoracic needle biopsy.World journal of radiology · 2026Article
- The value of dual-energy CT virtual monoenergetic imaging and metal-artifacts reduction system after metal plate correction of congenital funnel chest in child: a single center retrospective study.Frontiers in pediatrics · 2025Article
- Approaches, advantages, and challenges to photon counting detector and multi-energy CT.Abdominal radiology (New York) · 2024Review
- Simultaneous Activity and Attenuation Estimation in TOF-PET With TV-Constrained Nonconvex Optimization.IEEE transactions on medical imaging · 2024Article
- Influence of helical pitch and gantry rotation time on image quality and file size in ultrahigh-resolution photon-counting detector CT.Scientific reports · 2024Article
- Three-Dimensional Visualization of Shunt Valves with Photon Counting CT and Comparison to Traditional X-ray in a Simple Phantom Model.Tomography (Ann Arbor, Mich.) · 2024Article
- Dual energy CT reconstruction using the constrained one step spectral image reconstruction algorithm.Medical physics · 2024Article
- Simultaneous activity and attenuation estimation in TOF-PET with TV-constrained nonconvex optimization.ArXiv · 2024Article
- Assessment of material identification and quantification in the presence of metals using spectral photon counting CT.PloS one · 2024Article
- Convergence for nonconvex ADMM, with applications to CT imaging.Journal of machine learning research : JMLR · 2024Article
- Constrained one-step material decomposition reconstruction of head CT data from a silicon photon-counting prototype.Medical physics · 2023Article
- Direct Multi-Material Reconstruction via Iterative Proximal Adaptive Descent for Spectral CT Imaging.Bioengineering (Basel, Switzerland) · 2023Article
- Spectral calibration of photon-counting detectors at high photon flux.Medical physics · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
Abstract
purposeThe constrained one-step spectral CT image reconstruction (cOSSCIR) algorithm with a nonconvex alternating direction method of multipliers optimizer is proposed for addressing computed tomography (CT) metal artifacts caused by beam hardening, noise, and photon starvation. The quantitative performance of cOSSCIR is investigated through a series of photon-counting CT simulations.
methodscOSSCIR directly estimates basis material maps from photon-counting data using a physics-based forward model that accounts for beam hardening. The cOSSCIR optimization framework places constraints on the basis maps, which we hypothesize will stabilize the decomposition and reduce streaks caused by noise and photon starvation. Another advantage of cOSSCIR is that the spectral data need not be registered, so that a ray can be used even if some energy window measurements are unavailable. Photon-counting CT acquisitions of a virtual pelvic phantom with low-contrast soft tissue texture and bilateral hip prostheses were simulated. Bone and water basis maps were estimated using the cOSSCIR algorithm and combined to form a virtual monoenergetic image for the evaluation of metal artifacts. The cOSSCIR images were compared to a "two-step" decomposition approach that first estimated basis sinograms using a maximum likelihood algorithm and then reconstructed basis maps using an iterative total variation constrained least-squares optimization (MLE+TV
resultsNoiseless simulations demonstrated the convergence of the cOSSCIR and MLE+TV
conclusionsBy directly inverting photon-counting CT data into basis maps using an accurate physics-based forward model and a constrained optimization algorithm, cOSSCIR avoids metal artifacts due to beam hardening, noise, and photon starvation. The cOSSCIR algorithm demonstrated improved stability and accuracy compared to a two-step method of decomposition followed by reconstruction.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.