Evidence map›Paper›PMID 35318480›Full record

ArticleJournal of biomechanical engineering2022

Visions of TAVR Future: Development and Optimization of a Second Generation Novel Polymeric TAVR.

Brandon Kovarovic, Ryan Helbock, Kyle Baylous, Oren M Rotman, Marvin J Slepian, Danny Bluestein

Abstract read
In one paragraph

Article in Journal of biomechanical engineering, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Vortex Dynamics in the Sinus of Valsalva.Bioengineering (Basel, Switzerland) · 2025
    Article
  5. Review
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Nanotechnology in interventional cardiology: A state-of-the-art review.International journal of cardiology. Heart & vasculature · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Brandon KovarovicDepartment of Biomedical Engineering, Stony Brook University, T8-050 Health Sciences Center, Stony Brook, NY 11794-8084.
Ryan HelbockDepartment of Biomedical Engineering, Stony Brook University, T8-050 Health Sciences Center, Stony Brook, NY 11794-8084.
Kyle BaylousDepartment of Biomedical Engineering, Stony Brook University, T8-050 Health Sciences Center, Stony Brook, NY 11794-8084.
Oren M RotmanDepartment of Biomedical Engineering, Stony Brook University, T8-050 Health Sciences Center, Stony Brook, NY 11794-8084.
Marvin J SlepianDepartment of Medicine and Biomedical Engineering Sarver Heart Center, University of Arizona, Tucson, AZ 85721.
Danny BluesteinDepartment of Biomedical Engineering, Stony Brook University, T8-050 Health Sciences Center, Stony Brook, NY 11794-8084.

Funding

Biomechanical Approaches and Technologies for Enhancing TAVR OutcomesU01EB026414 · NIBIB · STATE UNIVERSITY NEW YORK STONY BROOK · PI BLUESTEIN, DANNY · 2018 to 2022
$3.8M
A Novel Polymeric Valve for Transcatheter Aortic Valve ReplacementR42HL134418 · NHLBI · POLYNOVA CARDIOVASCULAR, INC · PI BLUESTEIN, DANNY · 2020 to 2022
$2.0M
A Novel Polymeric Valve for Transcatheter Aortic Valve ReplacementR41HL134418 · NHLBI · POLYNOVA CARDIOVASCULAR, INC · PI BLUESTEIN, DANNY · 2017 to 2018
$225k
NHLBI NIH HHS R41 HL134418NHLBI NIH HHS R42 HL134418NIBIB NIH HHS U01 EB026414
6 · The paper itself

Abstract

Tissue-based transcatheter aortic valve (AV) replacement (TAVR) devices have been a breakthrough approach for treating aortic valve stenosis. However, with the expansion of TAVR to younger and lower risk patients, issues of long-term durability and thrombosis persist. Recent advances in polymeric valve technology facilitate designing more durable valves with minimal in vivo adverse reactions. We introduce our second-generation polymeric transcatheter aortic valve (TAV) device, designed and optimized to address these issues. We present the optimization process of the device, wherein each aspect of device deployment and functionality was optimized for performance, including unique considerations of polymeric technologies for reducing the volume of the polymer material for lower crimped delivery profiles. The stent frame was optimized to generate larger radial forces with lower material volumes, securing robust deployment and anchoring. The leaflet shape, combined with varying leaflets thickness, was optimized for reducing the flexural cyclic stresses and the valve's hydrodynamics. Our first-generation polymeric device already demonstrated that its hydrodynamic performance meets and exceeds tissue devices for both ISO standard and patient-specific in vitro scenarios. The valve already reached 900 × 106 cycles of accelerated durability testing, equivalent to over 20 years in a patient. The optimization framework and technology led to the second generation of polymeric TAV design- currently undergoing in vitro hydrodynamic testing and following in vivo animal trials. As TAVR use is rapidly expanding, our rigorous bio-engineering optimization methodology and advanced polymer technology serve to establish polymeric TAV technology as a viable alternative to the challenges facing existing tissue-based TAV technology.

Indexed as

Aortic Valve StenosisHeart Valve ProsthesisTranscatheter Aortic Valve ReplacementAnimalsAortic ValveHumansPolymersPolymers

Identifiers

PMID35318480
PMCPMC8990719

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.