ArticleJournal of biomechanical engineering2022
Visions of TAVR Future: Development and Optimization of a Second Generation Novel Polymeric TAVR.
Article in Journal of biomechanical engineering, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Clinical and Experimental Studies of Structural Valve Degeneration of Bovine Jugular Vein Valves: Mitigation with Polyoxazoline Modification.Pediatric cardiology · 2026Article
- Optimisation of Bioinspired Fibre Architectures for 3D-Printed Polymer Heart Valves via Melt Electrowriting (MEW) Using FE Modelling and Design of Experiments (FE-DOE).Biomimetics (Basel, Switzerland) · 2026Article
- Development of a Polymeric TAVR Device Tailored to Bicuspid Aortic Valve Patients Using In Silico Design Optimization and Evaluation.Annals of biomedical engineering · 2026Article
- Vortex Dynamics in the Sinus of Valsalva.Bioengineering (Basel, Switzerland) · 2025Article
- Polymeric Heart Valves: Do They Represent a Reliable Alternative to Current Prosthetic Devices?Polymers · 2025Review
- Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease: A Review of the Existing Literature.Cureus · 2025Review
- Thrombogenic Risk Assessment of Transcatheter Prosthetic Heart Valves Using a Fluid-Structure Interaction Approach.Computer methods and programs in biomedicine · 2024Article
- Recent advancements in polymeric heart valves: From basic research to clinical trials.Materials today. Bio · 2024Review
- Article
- Reduced Order Modeling for Real-Time Stent Deformation Simulations of Transcatheter Aortic Valve Prostheses.Annals of biomedical engineering · 2024Article
- In silico fatigue optimization of TAVR stent designs with physiological motion in a beating heart model.Computer methods and programs in biomedicine · 2024Article
- Polymeric Heart Valves Will Displace Mechanical and Tissue Heart Valves: A New Era for the Medical Devices.International journal of molecular sciences · 2023Review
- Designing a Novel Asymmetric Transcatheter Aortic Valve for Stenotic Bicuspid Aortic Valves Using Patient-Specific Computational Modeling.Annals of biomedical engineering · 2023Article
- Nanotechnology in interventional cardiology: A state-of-the-art review.International journal of cardiology. Heart & vasculature · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Tissue-based transcatheter aortic valve (AV) replacement (TAVR) devices have been a breakthrough approach for treating aortic valve stenosis. However, with the expansion of TAVR to younger and lower risk patients, issues of long-term durability and thrombosis persist. Recent advances in polymeric valve technology facilitate designing more durable valves with minimal in vivo adverse reactions. We introduce our second-generation polymeric transcatheter aortic valve (TAV) device, designed and optimized to address these issues. We present the optimization process of the device, wherein each aspect of device deployment and functionality was optimized for performance, including unique considerations of polymeric technologies for reducing the volume of the polymer material for lower crimped delivery profiles. The stent frame was optimized to generate larger radial forces with lower material volumes, securing robust deployment and anchoring. The leaflet shape, combined with varying leaflets thickness, was optimized for reducing the flexural cyclic stresses and the valve's hydrodynamics. Our first-generation polymeric device already demonstrated that its hydrodynamic performance meets and exceeds tissue devices for both ISO standard and patient-specific in vitro scenarios. The valve already reached 900 × 106 cycles of accelerated durability testing, equivalent to over 20 years in a patient. The optimization framework and technology led to the second generation of polymeric TAV design- currently undergoing in vitro hydrodynamic testing and following in vivo animal trials. As TAVR use is rapidly expanding, our rigorous bio-engineering optimization methodology and advanced polymer technology serve to establish polymeric TAV technology as a viable alternative to the challenges facing existing tissue-based TAV technology.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.