Evidence map›Paper›PMID 35317247›Full record

ArticleFrontiers in neurology2021

A Comparison of Energy-Efficient Seizure Detectors for Implantable Neurostimulation Devices.

Farrokh Manzouri, Marc Zöllin, Simon Schillinger, Matthias Dümpelmann, Ralf Mikut, Peter Woias, Laura Maria Comella, Andreas Schulze-Bonhage

Open access · goldAbstract read
In one paragraph

Article in Frontiers in neurology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
2.0field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 16 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Farrokh ManzouriEpilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Marc ZöllinLaboratory for Design of Microsystems, Department of Microsystems Engineering - IMTEK, University of Freiburg, Freiburg, Germany.
Simon SchillingerLaboratory for Design of Microsystems, Department of Microsystems Engineering - IMTEK, University of Freiburg, Freiburg, Germany.
Matthias DümpelmannEpilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Ralf MikutInstitute for Automation and Applied Informatics, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany.
Peter WoiasLaboratory for Design of Microsystems, Department of Microsystems Engineering - IMTEK, University of Freiburg, Freiburg, Germany.
Laura Maria ComellaLaboratory for Design of Microsystems, Department of Microsystems Engineering - IMTEK, University of Freiburg, Freiburg, Germany.
Andreas Schulze-BonhageEpilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
University Medical Center Freiburg · DEUniversity of Freiburg · DEKarlsruhe Institute of Technology · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: About 30% of epilepsy patients are resistant to treatment with antiepileptic drugs, and only a minority of these are surgical candidates. A recent therapeutic approach is the application of electrical stimulation in the early phases of a seizure to interrupt its spread across the brain. To accomplish this, energy-efficient seizure detectors are required that are able to detect a seizure in its early stages. Methods: Three patient-specific, energy-efficient seizure detectors are proposed in this study: (i) random forest (RF); (ii) long short-term memory (LSTM) recurrent neural network (RNN); and (iii) convolutional neural network (CNN). Performance evaluation was based on EEG data ( Results: The RNN seizure detector achieved a slightly better level of performance, with a median area under the precision-recall curve score of 0.49, compared to 0.47 for CNN and 0.46 for RF. In terms of energy consumption, RF was the most efficient algorithm, with a total of 67k AOs and 67k MAs per classification. This was followed by CNN (488k AOs and 963k MAs) and RNN (772k AOs and 978k MAs), whereby MAs contributed more to total energy consumption. Measurements derived from the hardware implementation of the RNN algorithm demonstrated a significant correlation between estimations and actual measurements. Discussion: All three proposed seizure detection algorithms were shown to be suitable for application in implantable devices. The applied methodology for a platform-independent energy estimation was proven to be accurate by way of hardware implementation of the RNN algorithm. These findings show that seizure detection can be achieved using just a few channels with limited spatial distribution. The methodology proposed in this study can therefore be applied when designing new models for responsive neurostimulation.

Indexed as

convolutional neural networklow-power hardware implementationrandom forestrecurrent neural networkresponsive neurostimulationseizure detection

Identifiers

PMID35317247
PMCPMC8934428
OpenAlexW4214850322

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.