ReviewJournal of minimal access surgery

Performance of three-dimensional and ultra-high-definition (4K) technology in laparoscopic surgery: A systematic review and meta-analysis.

Vitish Singla, Hemanga K Bhattacharjee, Ekansh Gupta, Deepti Singh, Ashwani K Mishra, Dalim Kumar

Abstract readReview
In one paragraph

Review in Journal of minimal access surgery. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Review
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. The Era of 4K Three-dimensional Imaging is Coming.Gynecology and minimally invasive therapy
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Vitish SinglaDepartment of Surgical Disciplines, All India Institute of Medical Sciences, New Delhi, India.
Hemanga K BhattacharjeeDepartment of Surgical Disciplines, All India Institute of Medical Sciences, New Delhi, India.
Ekansh GuptaDepartment of Surgical Disciplines, All India Institute of Medical Sciences, New Delhi, India.
Deepti SinghDepartment of Surgical Disciplines, All India Institute of Medical Sciences, New Delhi, India.
Ashwani K MishraNational Drug Dependence Treatment Centre, All India Institute of Medical Sciences, New Delhi, India.
Dalim KumarDepartment of Anesthesiology, All India Institute of Medical Sciences, New Delhi, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The technology in the field of laparoscopy is rapidly evolving and is primarily focussed on increasing the quality of image and depth perception in the form of 4K and three-dimensional (3D) technology. There has been no conclusion yet regarding the better technology. Methods: A systematic search was performed independently by two authors across MEDLINE, Google Scholar and Embase using the PRISMA guidelines. All randomised control trials comparing 3D and 4K technologies were included. Meta-analysis was conducted using random-effects statistics for time taken for different tasks across the studies. Results: The search strategy revealed a total of 1835 articles, out of which nine studies were included. Three studies showed no superiority of 3D over 4K, while the remaining six did. Meta-analysis for the time taken for peg transfer favoured 3D over 4K (overall effect: Z = 2.12; P = 0.03). Forest plots for time taken for suturing (Z = 1.3; P = 0.19) and knot tying (Z = 1.7; P = 0.09) also favoured 3D over 4K; the results however were statistically insignificant. Path length was reported by two studies and was found to be lesser in the 3D group. Two studies measured the workload by NASA/Surg-TLX score, which was lower in the 3D group. Visual side effects were found to be higher in the 3D group. Conclusion: 3D technology is likely to result in a shorter operative time and better efficiency of movement as compared to the 4K technology by the virtue of its better depth perception.