Evidence map›Paper›PMID 35310786›Full record

ArticleJournal of clinical orthopaedics and trauma2022

Clinical and radiological outcome of acute high-grade acromioclavicular joint dislocation: A retrospective cohort study on Hook plate versus arthroscopic assisted single coracoclavicular tunnel with DogBone™ button dual FiberTape® construct.

Sandesh Madi, Vivek Pandey, Sujayendra Murali, Kiran Acharya

Open access · greenAbstract read
In one paragraph

Article in Journal of clinical orthopaedics and trauma, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 2 pooled it
1.2field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 2 syntheses or guidelines pooled it, 8 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Sandesh MadiDepartment of Orthopaedics, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, 576104, Karnataka, India.
Vivek PandeyDepartment of Orthopaedics, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, 576104, Karnataka, India.
Sujayendra MuraliDepartment of Orthopaedics, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, 576104, Karnataka, India.
Kiran AcharyaDepartment of Orthopaedics, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, 576104, Karnataka, India.
Manipal Academy of Higher Education · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Hook plate (HP) is a popular implant of choice in the management of highgrade acute acromioclavicular joint (ACJ) dislocations. Recently, suspensory loop systems have drawn significant interest with comparable results and additionally does not warrant implant removal. However, no studies have compared the outcomes of HP vis-a-vis Dog Bone TM Button with dual FiberTape® (DB). Methods: 38 patients who underwent HP or Arthroscopic assisted single tunnel DB fixation to stabilize high-grade ACJ dislocations were retrospectively included in study for clinically and radiological evaluation at a minimum follow up of one year. American Shoulder and Elbow Society and Constant Murley scores were used for clinical assessment. The radiological evaluation was done by assessing quality of reduction, measuring coracoclavicular distance (CCD), and extent of subacromial erosion. Results: For final follow up evaluation, both HP and DB group had 16 patients each. The mean follow-up was 55.38 ± 10.9 and 32.88 ± 14.0 months in HP and DB group, respectively. No significant difference in mean ASES (p=0.71) and CM score (p=0.62) was found between the two groups. The DB group revealed higher CCD at the final follow-up compared to the HP group (p=0.01). Although statistically insignificant, there were more subluxations and dislocations in the DB group (37.5%) compared to the HP group (25%). The subacromial erosion was noted in all cases of the HP group at time of implant removal. Conclusion: Both groups revealed satisfactory functional and radiological outcome. However, the DB group showed a higher tendency of loss of reduction.

Indexed as

Acromioclavicular jointDislocationDogBone ButtonHook plateShoulder

Identifiers

PMID35310786
PMCPMC8924685
OpenAlexW4214908914

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.