ArticleMicrosystems & nanoengineering2022

Highly integrated watch for noninvasive continual glucose monitoring.

Tianrui Chang, Hu Li, Nianrong Zhang, Xinran Jiang, Xinge Yu, Qingde Yang, Zhiyuan Jin, Hua Meng, Lingqian Chang

Open access · goldAbstract read
In one paragraph

Article in Microsystems & nanoengineering, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
8.4field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 106 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Wearable Electrochemical Biosensors for Advanced Healthcare Monitoring.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Review
  8. Beyond Flexible: Unveiling the Next Era of Flexible Electronic Systems.Advanced materials (Deerfield Beach, Fla.) · 2024
    Review
  9. Review
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Review
  16. Review
  17. Article
  18. Noninvasive Glucose Sensing In Vivo.Sensors (Basel, Switzerland) · 2023
    Review
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 2 countries.

Tianrui Chang *Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083 China.
Hu Li *Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.
Nianrong Zhang *General Surgery Department & Obesity and Metabolic Disease Center, China-Japan Friendship Hospital, Beijing, 100029 China.
Xinran JiangKey Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083 China.
Xinge YuDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.ORCID 0000-0003-0522-1171
Qingde YangSense Future (HangZhou) Co., Ltd, Hangzhou, 311217 China.
Zhiyuan JinKey Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083 China.
Hua MengGeneral Surgery Department & Obesity and Metabolic Disease Center, China-Japan Friendship Hospital, Beijing, 100029 China.
Lingqian ChangKey Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083 China.
Beihang University · CNChina-Japan Friendship Hospital · CNCity University of Hong Kong · HKGroup Sense (China) · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This article reports a highly integrated watch for noninvasive continual blood glucose monitoring. The watch employs a Nafion-coated flexible electrochemical sensor patch fixed on the watchband to obtain interstitial fluid (ISF) transdermally at the wrist. This reverse iontophoresis-based extraction method eliminates the pain and inconvenience that traditional fingerstick blood tests pose in diabetic patients' lives, making continual blood glucose monitoring practical and easy. All electronic modules, including a rechargeable power source and other modules for signal processing and wireless transmission, are integrated onto a watch face-sized printed circuit board (PCB), enabling comfortable wearing of this continual glucose monitor. Real-time blood glucose levels are displayed on the LED screen of the watch and can also be checked with the smartphone user interface. With 23 volunteers, the watch demonstrated 84.34% clinical accuracy in the Clarke error grid analysis (zones A + B). In the near future, commercial products could be developed based on this lab-made prototype to provide the public with noninvasive continual glucose monitoring.

Indexed as

BiosensorsElectrical and electronic engineering

Identifiers

PMID35310514
PMCPMC8866463
OpenAlexW4214520323

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390