Evidence map›Paper›PMID 35308728›Full record

ArticleCureus2022

Morphometric Study of the Intracranial Segment of the Vertebral Artery.

Priya Dharshini, Gunapriya Raghunath, Karthikeyan Gurusamy, Zareena Begum, Savitha Dhamodaran, Balaji Karunakaran, Yuvaraj Maria Francis, Vandana Kaveripakkam

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 6 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Priya DharshiniAnatomy, Saveetha Institute of Medical and Technical Sciences, Chennai, IND.
Gunapriya RaghunathAnatomy, Saveetha Institute of Medical and Technical Sciences, Chennai, IND.
Karthikeyan GurusamyAnatomy, Saveetha Medical College, Chennai, IND.
Zareena BegumAnatomy, Saveetha Medical College, Chennai, IND.
Savitha DhamodaranAnatomy, Tagore Medical College, Chennai, IND.
Balaji KarunakaranAnatomy, Saveetha Medical College, Chennai, IND.
Yuvaraj Maria FrancisAnatomy, Saveetha Institute of Medical and Technical Sciences, Chennai, IND.
Vandana KaveripakkamAnatomy, Saveetha Medical College, Chennai, IND.
Tamil Nadu Dr. M.G.R. Medical University · INSaveetha University · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background The vertebral artery (VA) forms the caudal part of the circle of Willis and is responsible for one-third of the blood supply of the cerebellum, pons, middle ear, and the upper part of the spinal cord and its meninges. The highest potential risk of injury to VA during cervical pedicle screw implantation is at C3 and then at C6. Knowledge about the morphometry of VA provides a better understanding of clinical conditions such as vertebra basilar insufficiency (VBI). Similarly, the knowledge of variation in the VA is needed during cervical pedicle screw implantation, which possesses the highest potential risk to VA at the C3 level. The origin of the vertebral artery from the aortic arch reached the upper cervical vertebra than the vertebral artery of subclavian origin. The length of the VA is greater on the left side than the right-side artery. Understanding and reporting of the same are essential to creating awareness that can aid in endarterectomy, angioplasty, and radiological procedures. Variations are noted in morphometry between sides. Aim To determine the morphometry of the vertebral artery (VA) with emphasis on the fourth segment (V4) and its variations using computed tomography angiogram (CTA). Materials and methods This present retrospective study was conducted in the Departments of Anatomy and Radiology and Imaging Sciences, Saveetha Medical College and Hospital. Participants were patients who took a head and neck CT for various clinical reasons. About 50 CT images, 33 male and 17 females, were selected from the archives. The length, diameter, and entry level of VA were studied. The data were tabulated and statistically analyzed. Result The mean length of VA was 24.49 ± 3.02 (cm) on the left side and 24.28 ± 3.91 (cm) on the right side in female subjects and was found to be 22.78 ± 1.7 (cm) on the left side and 21.5 ± 2.7 (cm) on the right side in male subjects. The mean diameter of VA at the level of the foramen magnum was 0.32 ± 0.05 (cm) on the right side and 0.322 ± 0.07 (cm) on the left side in females, 0.3 ± 0.064 (cm) on the left side and 0.26 ± 0.086 (cm) on the right side in males. Conclusion The length of VA was found to be statistically more on the left side than on the right side. The variations in morphometry seen can aid in various surgical and radiological procedures.

Indexed as

computed tomographymorphometrysyncopevariationvertebral artery

Identifiers

PMID35308728
PMCPMC8918444
OpenAlexW4211147538

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.