Evidence map›Paper›PMID 35304791›Full record

ArticleJournal of cardiovascular electrophysiology2022

Fluoroscopic predictors of acceptable capture threshold during the implantation of the micra transcatheter pacing system.

Ikuko Togashi, Toshiaki Sato, Akiko Maeda, Takato Mohri, Yumi Katsume, Mika Tashiro, Yuichi Momose, Noriko Nonoguchi, Kyoko Hoshida, Yosuke Miwa and 2 more

Abstract read
In one paragraph

Article in Journal of cardiovascular electrophysiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Ikuko TogashiDivision of Advanced Arrhythmia Management, Kyorin University School of Medicine, Mitaka, Japan.ORCID 0000-0003-2552-3070
Toshiaki SatoDivision of Advanced Arrhythmia Management, Kyorin University School of Medicine, Mitaka, Japan.
Akiko MaedaDivision of Cardiology, The Second Department of Internal Medicine, Kyorin University School of Medicine, Mitaka, Japan.
Takato MohriDivision of Cardiology, The Second Department of Internal Medicine, Kyorin University School of Medicine, Mitaka, Japan.
Yumi KatsumeDivision of Cardiology, The Second Department of Internal Medicine, Kyorin University School of Medicine, Mitaka, Japan.
Mika TashiroDivision of Cardiology, The Second Department of Internal Medicine, Kyorin University School of Medicine, Mitaka, Japan.
Yuichi MomoseDivision of Cardiology, The Second Department of Internal Medicine, Kyorin University School of Medicine, Mitaka, Japan.
Noriko NonoguchiDivision of Cardiology, The Second Department of Internal Medicine, Kyorin University School of Medicine, Mitaka, Japan.
Kyoko HoshidaDivision of Cardiology, The Second Department of Internal Medicine, Kyorin University School of Medicine, Mitaka, Japan.
Yosuke MiwaDivision of Cardiology, The Second Department of Internal Medicine, Kyorin University School of Medicine, Mitaka, Japan.ORCID 0000-0003-1132-1072
Akiko UedaDivision of Advanced Arrhythmia Management, Kyorin University School of Medicine, Mitaka, Japan.
Kyoko SoejimaDivision of Cardiology, The Second Department of Internal Medicine, Kyorin University School of Medicine, Mitaka, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionFew predictors of low capture threshold before the deployment of the Micra transcatheter pacing system (Micra TPS) have been determined. We aimed to identify fluoroscopic predictors of an acceptable capture threshold before Micra TPS deployment.

methodsSixty patients were successfully implanted with Micra TPS. Before deployment, gooseneck appearance of the catheter shaft was quantified using the angle between the tangent line of the shaft and the cup during diastole in the right anterior oblique (RAO) view. The direction of the device cup toward the ventricular septum was evaluated using the angle between the cup and the horizontal plane in the left anterior oblique (LAO) view.

resultsOf the 95 deployments we evaluated, 56 achieved an acceptable capture threshold of ≤2.0 V at 0.24 ms. In this acceptable threshold group, the deflection angle of the gooseneck shaft was significantly larger and the device cup was placed more horizontally with a lower elevation angle compared with those in the high threshold group. A deflection angle of ≥6° and an elevation angle of ≤30° were identified as the predictors of an acceptable capture threshold after deployment. An acceptable capture threshold was achieved in 24/31 (77.4%) patients in whom either angle criterion was satisfied at the first deployment.

conclusionsDiastolic gooseneck appearance of the delivery catheter in the RAO view or near-horizontal direction in the LAO view predicts an acceptable capture threshold after deployment. The shape of the delivery catheter before deployment should be evaluated using multiple fluoroscopic views to ensure successful implantation of Micra TPS.

Indexed as

Pacemaker, ArtificialEquipment DesignFluoroscopyHumansTreatment Outcomecapture thresholdfluoroscopic viewgooseneck appearanceleadless pacemakerpacemaker implantation

Identifiers

PMID35304791
PMCPMC9315022

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.