Evidence map›Paper›PMID 35304672›Full record

ArticleMedical & biological engineering & computing2022

Automated method for real-time AMD screening of fundus images dedicated for mobile devices.

Sofien Ben Sayadia, Yaroub Elloumi, Rostom Kachouri, Mohamed Akil, Asma Ben Abdallah, Mohamed Hedi Bedoui

Open access · greenAbstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.6field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Sofien Ben SayadiaMedical Technology and Image Processing Laboratory, Faculty of Medicine, University of Monastir, Monastir, Tunisia. sofien.bensayadia@esiee.fr.ORCID http://orcid.org/0000-0001-8891-9334
Yaroub ElloumiMedical Technology and Image Processing Laboratory, Faculty of Medicine, University of Monastir, Monastir, Tunisia.
Rostom KachouriLIGM, University Gustave Eiffel, CNRS, ESIEE Paris, 77454 Marne-la-Vallée, Paris, France.
Mohamed AkilLIGM, University Gustave Eiffel, CNRS, ESIEE Paris, 77454 Marne-la-Vallée, Paris, France.
Asma Ben AbdallahMedical Technology and Image Processing Laboratory, Faculty of Medicine, University of Monastir, Monastir, Tunisia.
Mohamed Hedi BedouiMedical Technology and Image Processing Laboratory, Faculty of Medicine, University of Monastir, Monastir, Tunisia.
UniLaSalle Amiens (ESIEE-Amiens) · FRUniversity of Monastir · TNCentre National de la Recherche Scientifique · FR

Funding

Campus France 19G1408
6 · The paper itself

Abstract

Aged macular degeneration (AMD) leads to a progressive decline in visual acuity until reaching blindness. It is considered as an irreversible pathology where an early diagnosis remains crucial. However, the lack of ophthalmologists, the permanent increase in elderly people, and their limited mobility involves a delay in AMD diagnosis. In this paper, we propose an automated method for AMD screening. The proposed processing pipeline consists in applying the well-known Radon transform to the macula region in order to model the AMD lesions even with a moderate quality of smartphone-captured fundus images. Thereby, the relevant features are carefully selected, related to the main proprieties of drusens, and then provided to an SVM classifier. The implementation of the method into a smartphone associated to a fundus image capturing device leads to a mobile CAD system that performs higher performance AMD screening. Within this framework and to achieve a real-time implementation, an optimization approach is suggested in order to reduce the processing workload. The evaluation of our method is carried out through the three public STARE, REFUGE, and RFMiD databases. A 4-fold cross-validation approach is used to evaluate the method performance where accuracies of 100%, 95.2%, and 94.3% are respectively obtained with STARE, REFUGE, and RFMiD databases. Comparisons with the state-of-the-art methods in the literature are done. Thereafter, the robustness of the proposed method was evaluated and proved. We note that 100% accuracy was preserved despite the use of degraded quality fundus images as noisy and blurred. Moreover, the propounded method was implemented in S7-Edge and S9 Smartphone devices, where the execution times of 19 and 15 milliseconds were respectively achieved, which proves the AMD real-time detection. Taking advantage of its mobility, cost-effective, detection performance, and reduced execution time, our proposed method seems a good solution for real-time AMD screening on mobile devices.

Indexed as

Macular DegenerationAgedComputers, HandheldDatabases, FactualFundus OculiHumansRetinaAged macular degenerationDrusensFeature extractionFundus imagem-healthRadon transformReal-time

Identifiers

PMID35304672
OpenAlexW4220761022

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked