Evidence map›Paper›PMID 35303203›Full record

ArticleJournal of artificial organs : the official journal of the Japanese Society for Artificial Organs2022

Hypothermic circulatory arrest does not induce coagulopathy in vitro.

Hayato Ise, Kyohei Oyama, Shingo Kunioka, Tomonori Shirasaka, Hirotsugu Kanda, Payam Akhyari, Hiroyuki Kamiya

Open access · hybridAbstract read
In one paragraph

Article in Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Hypothermic circulatory arrest at 20 ℃ does not deteriorate coagulopathy compared to 28 ℃ in a pig model.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2025
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Hayato IseDepartment of Cardiac Surgery, Asahikawa Medical University, Midorigaoka-Higashi 2-1-1-1, Asahikawa, Hokkaido, 078-8510, Japan.
Kyohei OyamaDepartment of Cardiac Surgery, Asahikawa Medical University, Midorigaoka-Higashi 2-1-1-1, Asahikawa, Hokkaido, 078-8510, Japan. koyama@asahikawa-med.ac.jp.ORCID http://orcid.org/0000-0002-8478-4417
Shingo KuniokaDepartment of Cardiac Surgery, Asahikawa Medical University, Midorigaoka-Higashi 2-1-1-1, Asahikawa, Hokkaido, 078-8510, Japan.
Tomonori ShirasakaDepartment of Cardiac Surgery, Asahikawa Medical University, Midorigaoka-Higashi 2-1-1-1, Asahikawa, Hokkaido, 078-8510, Japan.
Hirotsugu KandaDepartment of Anesthesiology and Critical Care Medicine, Asahikawa Medical University, Asahikawa, Japan.
Payam AkhyariDepartment of Cardiovascular Surgery, Heinrich Heine University, Düsseldorf, Germany.
Hiroyuki KamiyaDepartment of Cardiac Surgery, Asahikawa Medical University, Midorigaoka-Higashi 2-1-1-1, Asahikawa, Hokkaido, 078-8510, Japan.
Asahikawa Medical University · JPAsahikawa Medical College Hospital · JPHeinrich Heine University Düsseldorf · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Hypothermic circulatory arrest (HCA) is an essential procedure during aortic surgery to protect organs; however, hypothermia is believed to cause coagulopathy, which is a major fatal complication. This study aimed to clarify the impact of hypothermia on coagulation by eliminating clinical biases in vitro. In the hypothermic storage study, blood samples from five healthy volunteers were stored at 37 ℃ (group N) for 3 h or at 20 ℃ for 2 h, followed by 1 h of rewarming at 37 ℃ (group H). Thromboelastography was performed before and after 3 h of storage. In the mock circulation loop (MCL) study, blood samples were placed in the MCL and (a) maintained at 37 ℃ for 4 h (group N, n = 5), or (b) cooled to 20 ℃ to simulate HCA with a 0.1 L/min flow rate for 3 h and then rewarmed to 37 ℃ (group H, n = 5). The total MCL duration was 4 h, and the flow rate was maintained at 1 L/min, except during HCA. Blood samples collected 15 min after the beginning and end of MCL were subjected to standard laboratory tests and rotational thromboelastometry analyses. Hypothermia had no impact on coagulation in both the hypothermic storage and MCL studies. MCL significantly decreased the platelet counts and clot elasticity in the INTEM and EXTEM assays; however, there was no effect on fibrinogen contribution measured by FIBTEM. Hypothermia does not cause irreversible coagulopathy in vitro; however, MCL decreases coagulation due to the deterioration of platelets.

Indexed as

Blood Coagulation DisordersHeart ArrestHypothermiaBlood CoagulationFibrinogenHumansThrombelastographyFibrinogenBleedingCardiopulmonary bypassCoagulopathyHypothermic circulatory arrestIn vitro study

Identifiers

PMID35303203
PMCPMC9643254
OpenAlexW4221134879

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.