Effects of a reduction of the number of electrodes in the EEG montage on the number of identified seizure patterns.

Moritz Tacke, Katharina Janson, Katharina Vill, Florian Heinen, Lucia Gerstl, Karl Reiter, Ingo Borggraefe

Abstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Moritz TackeDivision of Pediatric Neurology, Developmental Neurology and Social Pediatrics, Department of Pediatrics, Dr. von Hauner Children's Hospital, University Hospital LMU Munich, Lindwurmstr. 4, 80337, Munich, Germany. moritz.tacke@med.uni-muenchen.de.
Katharina JansonDivision of Pediatric Neurology, Developmental Neurology and Social Pediatrics, Department of Pediatrics, Dr. von Hauner Children's Hospital, University Hospital LMU Munich, Lindwurmstr. 4, 80337, Munich, Germany.
Katharina VillDivision of Pediatric Neurology, Developmental Neurology and Social Pediatrics, Department of Pediatrics, Dr. von Hauner Children's Hospital, University Hospital LMU Munich, Lindwurmstr. 4, 80337, Munich, Germany.
Florian HeinenDivision of Pediatric Neurology, Developmental Neurology and Social Pediatrics, Department of Pediatrics, Dr. von Hauner Children's Hospital, University Hospital LMU Munich, Lindwurmstr. 4, 80337, Munich, Germany.
Lucia GerstlDivision of Pediatric Neurology, Developmental Neurology and Social Pediatrics, Department of Pediatrics, Dr. von Hauner Children's Hospital, University Hospital LMU Munich, Lindwurmstr. 4, 80337, Munich, Germany.
Karl ReiterDivision of Pediatric Intensive Care, Department of Pediatrics, Dr. von Hauner Children's Hospital, University Hospital LMU Munich, Lindwurmstr. 4, 80337, Munich, Germany.
Ingo BorggraefeDivision of Pediatric Neurology, Developmental Neurology and Social Pediatrics, Department of Pediatrics, Dr. von Hauner Children's Hospital, University Hospital LMU Munich, Lindwurmstr. 4, 80337, Munich, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Continuous EEG monitoring (cEEG) is frequently used in neurocritical care. The detection of seizures is one of the main objectives. The placement of the EEG electrodes is time consuming, therefore a reduced montage might lead to an increased availability in the ICU setting. It is unknown whether such a reduction of electrodes reduces the number of seizure patterns that are detected. A total of 95 seizure and 95 control EEG sequences from a pediatric epilepsy monitoring unit (EMU) were anonymized and reduced to an eight-lead montage. Two experts evaluated the recordings and the seizure detection rates using the reduced and the full montage were compared. Sensitivity and specificity for the seizure detection were calculated using the original EMU findings as gold standard. The sensitivity to detect seizures was 0.65 for the reduced montage compared to 0.76 for the full montage (p = 0.031). The specificities (0.97 and 0.96) were comparable (p = 1). A total of 4/9 (44%) of the generalized, 12/44 (27%) of the frontal, 6/14 (43%) of the central, 0/1 (0%) of the occipital, 6/20 (30%) of the temporal, and 5/7 (71%) of the parietal seizure patterns were not detected using the reduced montage. The median time difference between the onset of the seizure pattern in the full and reduced montage was 0.026s (IQR 5.651s). In this study the reduction of the EEG montage from 21 to eight electrodes reduced the sensitivity to detect seizure patterns from 0.76 to 0.65. The specificity remained virtually unchanged.

Indexed as

ElectroencephalographySeizuresChildElectrodesHumansMonitoring, PhysiologicSensitivity and Specificity

Identifiers

PMID35301386
PMCPMC8930978

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.