Evidence map›Paper›PMID 35296950›Full record

ArticleInternational journal of computer assisted radiology and surgery2022

Real-time vessel segmentation and reconstruction for virtual fixtures for an active handheld microneurosurgical instrument.

Aravind Venugopal, Sara Moccia, Simone Foti, Arpita Routray, Robert A MacLachlan, Alessandro Perin, Leonardo S Mattos, Alexander K Yu, Jody Leonardo, Elena De Momi and 1 more

Abstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Aravind VenugopalDepartment of Computer Science, BITS Pilani, Pilani, Goa, India.
Sara MocciaThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy.
Simone FotiDepartment of Computer Science, University College London, London, UK.
Arpita RoutrayRobotics Institute, Carnegie Mellon University, Pittsburgh, PA, USA.
Robert A MacLachlanRobotics Institute, Carnegie Mellon University, Pittsburgh, PA, USA.
Alessandro PerinIstituto Neurologico Carlo Besta, Milan, Italy.
Leonardo S MattosDepartment of Advanced Robotics, Istituto Italiano di Tecnologia, Genoa, Italy.
Alexander K YuAllegheny Health Network, Pittsburgh, PA, USA.
Jody LeonardoAllegheny Health Network, Pittsburgh, PA, USA.
Elena De MomiDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.
Cameron N RiviereRobotics Institute, Carnegie Mellon University, Pittsburgh, PA, USA. camr@ri.cmu.edu.ORCID http://orcid.org/0000-0002-6749-3140

Funding

An Active Handheld MicromanipulatorR01EB000526 · NIBIB · CARNEGIE-MELLON UNIVERSITY · PI RIVIERE, CAMERON N · 2003 to 2017
$2.6M
Multi-Frequency Tracker for Control of Handheld Surgical Robotic SystemsR01EB024564 · NIBIB · CARNEGIE-MELLON UNIVERSITY · PI RIVIERE, CAMERON N · 2018 to 2021
$1.4M
NIBIB NIH HHS R01 EB000526NIBIB NIH HHS R01 EB024564NIH HHS R01EB000526NIH HHS R01EB024564
6 · The paper itself

Abstract

purposeComplications related to vascular damage such as intra-operative bleeding may be avoided during neurosurgical procedures such as petroclival meningioma surgery. To address this and improve the patient's safety, we designed a real-time blood vessel avoidance strategy that enables operation on deformable tissue during petroclival meningioma surgery using Micron, a handheld surgical robotic tool.

methodsWe integrated real-time intra-operative blood vessel segmentation of brain vasculature using deep learning, with a 3D reconstruction algorithm to obtain the vessel point cloud in real time. We then implemented a virtual-fixture-based strategy that prevented Micron's tooltip from entering a forbidden region around the vessel, thus avoiding damage to it.

resultsWe achieved a median Dice similarity coefficient of 0.97, 0.86, 0.87 and 0.77 on datasets of phantom blood vessels, petrosal vein, internal carotid artery and superficial vessels, respectively. We conducted trials with deformable clay vessel phantoms, keeping the forbidden region 400 [Formula: see text]m outside and 400 [Formula: see text]m inside the vessel. Micron's tip entered the forbidden region with a median penetration of just 8.84 [Formula: see text]m and 9.63 [Formula: see text]m, compared to 148.74 [Formula: see text]m and 117.17 [Formula: see text]m without our strategy, for the former and latter trials, respectively.

conclusionReal-time control of Micron was achieved at 33.3 fps. We achieved improvements in real-time segmentation of brain vasculature from intra-operative images and showed that our approach works even on non-stationary vessel phantoms. The results suggest that by enabling precise, real-time control, we are one step closer to using Micron in real neurosurgical procedures.

Indexed as

Meningeal NeoplasmsMeningiomaAlgorithmsHumansNeurosurgical ProceduresPhantoms, ImagingHandheld robotic toolsNeurosurgeryReal-time intra-operative vessel segmentationRobot-assisted surgeryVirtual fixture control

Identifiers

PMID35296950
PMCPMC11285625

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.