ArticleJMIR medical informatics2022
Using a Convolutional Neural Network and Convolutional Long Short-term Memory to Automatically Detect Aneurysms on 2D Digital Subtraction Angiography Images: Framework Development and Validation.
Article in JMIR medical informatics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 12 citations in OpenAlex.
- Intracranial aneurysm segmentation on digital subtraction angiography: a retrospective and multi-center study.Frontiers in neurology · 2025Article
- Generalization of a Deep Learning Model for Continuous Glucose Monitoring-Based Hypoglycemia Prediction: Algorithm Development and Validation Study.JMIR medical informatics · 2024Article
- AI-Powered Diagnosis of Skin Cancer: A Contemporary Review, Open Challenges and Future Research Directions.Cancers · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIt is hard to distinguish cerebral aneurysms from overlapping vessels in 2D digital subtraction angiography (DSA) images due to these images' lack of spatial information.
objectiveThe aims of this study were to (1) construct a deep learning diagnostic system to improve the ability to detect posterior communicating artery aneurysms on 2D DSA images and (2) validate the efficiency of the deep learning diagnostic system in 2D DSA aneurysm detection.
methodsWe proposed a 2-stage detection system. First, we established the region localization stage to automatically locate specific detection regions of raw 2D DSA sequences. Second, in the intracranial aneurysm detection stage, we constructed a bi-input+RetinaNet+convolutional long short-term memory (C-LSTM) framework to compare its performance for aneurysm detection with that of 3 existing frameworks. Each of the frameworks had a 5-fold cross-validation scheme. The receiver operating characteristic curve, the area under the curve (AUC) value, mean average precision, sensitivity, specificity, and accuracy were used to assess the abilities of different frameworks.
resultsA total of 255 patients with posterior communicating artery aneurysms and 20 patients without aneurysms were included in this study. The best AUC values of the RetinaNet, RetinaNet+C-LSTM, bi-input+RetinaNet, and bi-input+RetinaNet+C-LSTM frameworks were 0.95, 0.96, 0.92, and 0.97, respectively. The mean sensitivities of the RetinaNet, RetinaNet+C-LSTM, bi-input+RetinaNet, and bi-input+RetinaNet+C-LSTM frameworks and human experts were 89% (range 67.02%-98.43%), 88% (range 65.76%-98.06%), 87% (range 64.53%-97.66%), 89% (range 67.02%-98.43%), and 90% (range 68.30%-98.77%), respectively. The mean specificities of the RetinaNet, RetinaNet+C-LSTM, bi-input+RetinaNet, and bi-input+RetinaNet+C-LSTM frameworks and human experts were 80% (range 56.34%-94.27%), 89% (range 67.02%-98.43%), 86% (range 63.31%-97.24%), 93% (range 72.30%-99.56%), and 90% (range 68.30%-98.77%), respectively. The mean accuracies of the RetinaNet, RetinaNet+C-LSTM, bi-input+RetinaNet, and bi-input+RetinaNet+C-LSTM frameworks and human experts were 84.50% (range 69.57%-93.97%), 88.50% (range 74.44%-96.39%), 86.50% (range 71.97%-95.22%), 91% (range 77.63%-97.72%), and 90% (range 76.34%-97.21%), respectively.
conclusionsAccording to our results, more spatial and temporal information can help improve the performance of the frameworks. Therefore, the bi-input+RetinaNet+C-LSTM framework had the best performance when compared to that of the other frameworks. Our study demonstrates that our system can assist physicians in detecting intracranial aneurysms on 2D DSA images.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.