Evidence map›Paper›PMID 35291508›Full record

ArticleAmerican journal of cardiovascular disease2022

FFR pressure wire comparative study for drift: piezo resistive versus optical sensor.

Daan Cottens, Bert Ferdinande, Jawed Polad, Mathias Vrolix, Koen Ameloot, Ief Hendrickx, Ella Poels, Joren Maeremans, Jo Dens

Abstract read
In one paragraph

Article in American journal of cardiovascular disease, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Daan CottensDepartment of Cardiology, Hospital Oost-Limburg Genk, Belgium.
Bert FerdinandeDepartment of Cardiology, Hospital Oost-Limburg Genk, Belgium.
Jawed PoladDepartment of Cardiology, Hospital Jeroen Bosch's Hertogenbosch The Netherlands.
Mathias VrolixDepartment of Cardiology, Hospital Oost-Limburg Genk, Belgium.
Koen AmelootDepartment of Cardiology, Hospital Oost-Limburg Genk, Belgium.
Ief HendrickxDepartment of Cardiology, Hospital Oost-Limburg Genk, Belgium.
Ella PoelsDepartment of Cardiology, Hospital Oost-Limburg Genk, Belgium.
Joren MaeremansFaculty of Medicine and Life Sciences, Universiteit Hasselt Belgium.
Jo DensDepartment of Cardiology, Hospital Oost-Limburg Genk, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study aimed to assess the stability of pressure derived fractional flow reserve (FFR) measurement and the handling performance of the OptoWire Deux with an optical pressure sensor relative to the PressureWire X with piezo resistive pressure sensors.

methodsThis multicenter centre observational study included 50 patients between June 2017 and November 2018 undergoing a diagnostic coronary angiography with FFR measurement of moderate to severe lesions. The reliability of FFR measurement measured with the OptoWire Deux relative to the PressureWire X in each lesion was assessed by the presence of drift. Handling characteristics for both pressure wires were assessed by a 5-point scale and by comparing the time between equalization and crossing the distal target lesion.

resultsHundred and sixteen measurements in 50 patients were performed. Very stable and reliable FFR measurements with the optical sensors were registered, relative to the piezo resistive pressure sensors. There is statistically significant difference in favor of the OptoWire Deux over the PressureWire X (P=0.001). However, the differences are small, when drift values were compared as continuous variables, no statistically significant difference was found for both directional (P=0.435) as for absolute drift (P=0.058).

conclusionsIn patients undergoing FFR measurement, both optical sensor pressure wires (Optowire Deux) as piezo resistive sensor pressure wires (PressureWire X) generate stable and reliable pressure and thus FFR measurement. The optical pressure sensor is less susceptible for drift relative to the piezo resistive pressure sensor, but the difference is within an acceptable range.