Evidence map›Paper›PMID 35289779›Full record

ArticleOperative neurosurgery (Hagerstown, Md.)2022

Placement of Stereotactic Electroencephalography Depth Electrodes Using the Stealth Autoguide Robotic System: Technical Methods and Initial Results.

Angelique Sao-Mai S Tay, Simon A Menaker, Julie L Chan, Adam N Mamelak

Abstract read
In one paragraph

Article in Operative neurosurgery (Hagerstown, Md.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors.

Angelique Sao-Mai S TayDepartment of Neurosurgery, Cedars-Sinai Medical Center, Los Angeles, California, USA.ORCID 0000-0002-6604-8897
Simon A MenakerDepartment of Neurosurgery, Cedars-Sinai Medical Center, Los Angeles, California, USA.
Julie L ChanDepartment of Neurosurgery, Cedars-Sinai Medical Center, Los Angeles, California, USA.
Adam N MamelakDepartment of Neurosurgery, Cedars-Sinai Medical Center, Los Angeles, California, USA.

Funding

Neuronal mechanisms of human episodic memoryU01NS117839 · NINDS · CEDARS-SINAI MEDICAL CENTER · PI MAMELAK, ADAM NATHANIEL, RUTISHAUSER, UELI · 2020 to 2024
$7.8M
NINDS NIH HHS U01 NS117839
6 · The paper itself

Abstract

backgroundRobotic systems are gaining acceptance as a preferred tool for the placement of electrodes for stereotactic electroencephalography (SEEG) studies.

objectiveTo describe the technical methods for insertion of SEEG using the Medtronic Stealth Autoguide robotic system and detailed outcomes in the initial 9 patients implanted.

methodsNine patients underwent placement of electrodes for SEEG studies with the use of the Autoguide system. Patients had at least 10 electrodes placed. Targets were planned on a Stealth S8 planning station, and electrodes were placed under general anesthesia. A technique for placement is described in detail. Patient outcomes and accuracy of electrode placement were evaluated. Methods to improve accuracy were investigated. Comparison of postoperative MRIs with preoperative planning MRIs was performed to determine the accuracy of electrode placement.

resultsOne hundred two electrodes were placed in 9 patients. Methods for placement and technical nuances are detailed. The distance from the planned target to the actual position of the electrode tip was measured in 8 of the 9 patients. The mean Euclidean distance was 4.67 ± 0.27 mm. There was 1 placement-related hemorrhage deficit in the first patient, and no deaths or infections. Adequate positioning of electrodes for seizure monitoring was obtained in all patients.

conclusionAutoguide can be used for placement of electrodes for SEEG studies with acceptable degrees of patient safety, accuracy, and efficiency. Considering the cost of Autoguide compared with other robotic devices, it may be attractive option.

Indexed as

Robotic Surgical ProceduresStereotaxic TechniquesElectrodes, ImplantedElectroencephalographyHumansImaging, Three-Dimensional

Identifiers

PMID35289779
PMCPMC10602512

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.