ArticleOperative neurosurgery (Hagerstown, Md.)2022
Placement of Stereotactic Electroencephalography Depth Electrodes Using the Stealth Autoguide Robotic System: Technical Methods and Initial Results.
Article in Operative neurosurgery (Hagerstown, Md.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Early Clinical Experience with the Stealth Autoguide Cranial Robotic Guidance Platform for Stereotactic Brain Biopsy.Journal of Korean Neurosurgical Society · 2026Article
- A markerless, real-time, augmented reality-based surgical navigation system for neurosurgical biopsies.Acta neurochirurgica · 2026Article
- Review
- Clinical experiences and learning curves from robot-assisted neurosurgical biopsies with Stealth Autoguide™.Neuro-oncology advancesArticle
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
4 authors.
Funding
Abstract
backgroundRobotic systems are gaining acceptance as a preferred tool for the placement of electrodes for stereotactic electroencephalography (SEEG) studies.
objectiveTo describe the technical methods for insertion of SEEG using the Medtronic Stealth Autoguide robotic system and detailed outcomes in the initial 9 patients implanted.
methodsNine patients underwent placement of electrodes for SEEG studies with the use of the Autoguide system. Patients had at least 10 electrodes placed. Targets were planned on a Stealth S8 planning station, and electrodes were placed under general anesthesia. A technique for placement is described in detail. Patient outcomes and accuracy of electrode placement were evaluated. Methods to improve accuracy were investigated. Comparison of postoperative MRIs with preoperative planning MRIs was performed to determine the accuracy of electrode placement.
resultsOne hundred two electrodes were placed in 9 patients. Methods for placement and technical nuances are detailed. The distance from the planned target to the actual position of the electrode tip was measured in 8 of the 9 patients. The mean Euclidean distance was 4.67 ± 0.27 mm. There was 1 placement-related hemorrhage deficit in the first patient, and no deaths or infections. Adequate positioning of electrodes for seizure monitoring was obtained in all patients.
conclusionAutoguide can be used for placement of electrodes for SEEG studies with acceptable degrees of patient safety, accuracy, and efficiency. Considering the cost of Autoguide compared with other robotic devices, it may be attractive option.