Evidence map›Paper›PMID 35287754›Full record

ArticleKnee surgery & related research2022

Agreement and accuracy of radiographic assessment using a decision aid for medial Oxford partial knee replacement: multicentre study.

Takafumi Hiranaka, Ryosuke Furuhashi, Kenichiro Takashiba, Takao Kodama, Kazuhiko Michishita, Hiroshi Inui, Eita Togashi

Abstract read
In one paragraph

Article in Knee surgery & related research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Takafumi HiranakaDepartment of Orthopaedic Surgery and Joint Surgery Centre, Takatsuki General Hospital, 1-3-13 Kosobe, Takatski City, Osaka, 569-1192, Japan. Takafumi.hiranaka@gmail.com.ORCID http://orcid.org/0000-0003-4916-6071
Ryosuke FuruhashiDepartment of Orthopaedic Surgery, Japanese Red Cross Hamamatsu Hospital, 1088-1 Kobayashi, Hamakita-ku, Hamamatsu City, Shizuoka, 434-8533, Japan.
Kenichiro TakashibaDepartment of Joint Reconstruction Center, Souseikai Fukuoka Mirai Hospital, 3-5-1, Kashiiteriha, Higashi-ku, Fukuoka City, Fukuoka, 813-0017, Japan.
Takao KodamaDepartment of Orthopaedic Surgery, Japan Community Healthcare Organization Saitama Medical Center, 4-9-3 Kitaurawa Urawa-ku, Saitama, 330-0074, Japan.
Kazuhiko MichishitaDepartment of Orthopaedic Surgery, Japan Community Healthcare Organization Yugawara Hospital, 2-21-6 Chuo, Yugawara, Kanagawa, 259-0396, Japan.
Hiroshi InuiDepartment of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan.
Eita TogashiDepartment of Orthopedic Surgery, Yamagata Tokushukai Hospital, 2-3-51 Kiyozumimachi, Yamagata city, Yamagata, 990-0834, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIndication for mobile-bearing partial knee replacement (PKR) is made on the basis of a radiological decision aid. This study aimed to reveal the inter-rater reproducibility and accuracy of the decision aid when used by experienced surgeons. PATIENTS AND

methodsAnonymised radiographic image sets (anteroposterior, lateral, varus/valgus stress in 20° knee flexion, and skyline views) from 20 consecutive patients who underwent knee replacement were assessed by 12 experienced surgeons. Agreements of each section and accuracy were compared by intra-operative inspection of the status of the anterior cruciate ligament (ACL) and medial and lateral cartilage according to the protocol of Radiographic Assessment for Medial Oxford PKR. Fleiss' kappa (κ) values were used as a statistical measure.

resultsFull-thickness medial cartilage had the best agreement between the surgeons (κ = 94.7%) and best accuracy (94.2%). Although functioning ACL (90.8%), intact cartilage (91.7%) and full-thickness lateral cartilage defects (86.1%) were accurately diagnosed, diagnoses of deficient ACL (up to 42.5%) and partial-thickness lateral cartilage defects (11.7%) were poor; they were sometimes misdiagnosed as being intact. Moreover, agreement of lateral and valgus stress radiographs regarding intact MCL function, as well as the overall decision, was considered to be inadequate (κ = 0.47, 0.58 and 0.51, respectively).

conclusionsAlthough the radiological aid is useful for selection of patients who are likely to be suitable for PKR, surgeons should still carefully assess the lateral weight-bearing area for partial-thickness loss and deficiency of the ACL because they were sometimes overlooked by surgeons using radiographs. MRI will be helpful to improve the accuracy of determination of Oxford PKR indication.

Indexed as

IndicationOperationRadiographyUnicompartmental knee arthroplasty

Identifiers

PMID35287754
PMCPMC8919622

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.