Evidence map›Paper›PMID 35287743›Full record

ArticleBiomaterials research2022

Evaluating the validity of lightweight talar replacement designs: rational models and topologically optimized models.

Yeokyung Kang, Seongjin Kim, Jungsung Kim, Jin Woo Lee, Jong-Chul Park

Open access · goldAbstract read
In one paragraph

Article in Biomaterials research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.3field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Design of a lightweight universal talus implant using topology optimization.Frontiers in bioengineering and biotechnology · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Yeokyung KangCentral Research & Development Center, Corentec Company, Limited, Seoul, Republic of Korea.
Seongjin KimCentral Research & Development Center, Corentec Company, Limited, Seoul, Republic of Korea.
Jungsung KimCentral Research & Development Center, Corentec Company, Limited, Seoul, Republic of Korea.
Jin Woo LeeDepartment of Orthopaedic Surgery, Yonsei University College of Medicine, Seoul, Republic of Korea.
Jong-Chul ParkCellbiocontrol Laboratory, Department of Medical Engineering, Yonsei University College of Medicine, Seoul, Republic of Korea. parkjc@yuhs.ac.ORCID http://orcid.org/0000-0003-0083-5991
Yonsei University · KRKorea Pharma (South Korea) · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTotal talar replacement is normally stable and satisfactory. We studied a rational scaffold talus model for each size range created through topology optimization (TO) and comparatively evaluated a topologically optimized scaffold bone talus model using a finite element analysis (FEA). We hypothesized that the rational scaffold would be more effective for application to the actual model than the topologically optimized scaffold.

methodsSize specification for the rational model was performed via TO and inner scaffold simplification. The load condition for worst-case selection reflected the peak point according to the ground reaction force tendency, and the load directions "plantar 10°" (P10), "dorsi 5°" (D5), and "dorsi 10°" (D10) were applied to select worst-case scenarios among the P10, D5, and D10 positions (total nine ranges) of respective size specifications. FEA was performed on each representative specification-standard model, reflecting a load of 5340 N. Among the small bone models selected as the worst-case, an arbitrary size was selected, and the validity of the standard model was evaluated. The standard model was applied to the rational structure during validity evaluation, and the TO model reflecting the internal structure derived by the TO of the arbitrary model was implemented.

resultIn worst-case selection, the highest peak von Mises stress (PVMS) was calculated from the minimum D5 model (532.11 MPa). Thereafter, FEA revealed peak von Mises stress levels of 218.01 MPa and 565.35 MPa in the rational and topologically optimized models, respectively, confirming that the rational model yielded lower peak von Mises stress. The weight of the minimum model was reduced from 1106 g to 965.4 g after weight reduction through rational scaffold application.

conclusionThe rational inner-scaffold-design method is safer than topologically optimized scaffold design, and three types of rational scaffold, according to each size range, confirmed that all sizes of the talus within the anatomical dimension could be covered, which was a valid result in the total talar replacement design. Accordingly, we conclude that an implant design meeting the clinical design requirements, including patient customization, weight reduction, and mechanical stability, should be possible by applying a rational inner scaffold without performing TO design. The scaffold model weight was lower than that of the solid model, and the safety was also verified through FEA.

Indexed as

Finite element analysisOptimized scaffoldRational scaffoldTalar replacementTopology optimization

Identifiers

PMID35287743
PMCPMC8919543
OpenAlexW4220793300

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.