ArticleAnalytical sciences : the international journal of the Japan Society for Analytical Chemistry2022
Reducing the channel diameter of polydimethylsiloxane fluidic chips made by a 3D-printed sacrificial template and their application for flow-injection analysis.
Article in Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 1 citations in OpenAlex.
- Solvent-based post-processing to fill layer gaps in FFF-printed polypropylene fluidic chips and their application to flow injection analysis.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2026Article
- Radioactive isotope separation with 3D-printed flow-based device.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Fluidic chips have attracted considerable interest in recent years for their potential applications in analytical devices. Previously, we developed a method to fabricate polydimethylsiloxane (PDMS) fluidic chips via templates made using a low-priced commercial Fused Deposition Modeling (FDM) type 3D printer and polymer coatings. However, in general, methods using a template cannot form a flow channel thinner than the template thickness and the width. In this study, the inner wall of a PDMS fluidic chip was coated with PDMS to create a chip with a channel inner diameter smaller than a template. Then, by measuring the flow signal of methyl orange with a single line, the basic properties of the non-coated and coated chip were investigated. As a result, almost the same flow profile was obtained in non-coated and coated chips at the same linear velocity and the same sample injection length. By coating and narrowing the channel width, it is possible to save the amount of sample and carrier solution. Measuring hydrazine in water using a coated chip was also tried. The calibration curve indicated good linearity in the range of 1-6 ppm. However, a concentration point of 7 ppm deviated. The reason for this deviation was presumably due to inadequate mixing of the sample and reagent. By decreasing the flow rate, the calibration curve indicated good linearity in the range of 1-7 ppm.